Custom Script File Options - HP BL860c Deployment Manual

For integrity servers with linux
Hide thumbs Also See for BL860c:
Table of Contents

Advertisement

Size = [N]|Max
Sectors = 32|63
StripeSize = 8|16|32|64|128|256
ArrayAccelerator= Enable|Disable
ResourceVolumeOwner= N
LogicalDriveSSPState = Enable|Disable
SSPAdaptersWithAccess = [N],[N]...|None
PreferredPath = 1|2
; HBA Options
; There can be multiple HBA specifications in the file
HBA_WW_ID = WWN
ConnectionName = UserDefinedName
HostMode = Default|Windows|Windows(degrade
|OpenVMS|Tru64|Linux|Solaris|Netware|HP|Windows_SP2_and_
Table 6-7 Custom Script File Options
Option
Action
Method
Controller
ClearConfigurationWithDataLoss
Value
Defines if you are changing existing arrays and logical drives or adding new
ones. This option is required.
Configure: Existing arrays are not modified. Only new arrays and new logical
drives can be created in this mode.
Reconfigure: Existing arrays and logical drives might be modified in a
non-data-destructive manner. You can create new arrays, expand existing arrays,
create new logical drives, migrate existing logical drives, and extend existing
logical drives
If the -i-with-reset or -reset command line switch is used, the existing
controller configuration is cleared with data loss as the first step in the
configurations process, regardless of the setting of the Action mode.
Defines if you are in Automatic or Custom mode.
Specify Custom for a custom script.
Identifies to which controllers to apply the configuration. This option is required.
Slot [N][:N]: The internal controller with slot number N is used. External
controllers can be identified by appending the Port Number. For example, an
MSA1500 connected to a SA6402 might be found at "Slot 4:2," where 4 is the
internal Slot number and 2 is the SCSI port.
WWN [N]: The external controller with World-Wide Name(WWN) N is used.
SerialNumber [N]: The shared storage controller with serial number N is
used.
All: All detected internal and external controllers in the system are used.
First: The first controller found, based on the controller with the lowest PCI
slot number.
IOCabinet [N], IOBay [N], IOChassis [N],Slot [N], Cabinet
[N], Cell [N]: The controller identified by the IPF Slot path information is
used.
Use of the -internal" and -external command line switches influences
what is regarded as the first controller. For example, if the -external switch
is used, the first controller is the first external controller discovered, regardless
of the number of internal controllers in the host system.
Specifies if the configuration should be cleared. This option causes data loss
since it deletes all logical drives on the controller. Other scripting commands
can exist after this option to recreate a new configuration. This option is optional.
Yes: The configuration is cleared. All arrays and logical drives on the controller
are deleted.
No: The configuration is not cleared. This is the default option if the command
is not specified in the script file