Safety Instructions - Craftsman 82345 Owner's Manual

Manual ranging multimeter
Hide thumbs Also See for 82345:
Table of Contents

Advertisement

SAFETY INSTRUCTIONS

This meter has been designed for safe use, but must be
operated with caution. The rules listed below must be carefully
followed for safe operation.
1.
NEVER apply voltage or current to the meter that exceeds the specified
maximum:
Function
V DC or V AC
mA DC
A DC
Resistance, Diode Test,
Continuity
2.
USE EXTREME CAUTION when working with high voltages.
3.
DO NOT measure voltage if the voltage on the "COM" input jack
exceeds 600V above earth ground.
4.
NEVER connect the meter leads across a voltage source while the
function switch is in the current, resistance, or diode mode. Doing so can
damage the meter.
5.
ALWAYS discharge filter capacitors in power supplies and disconnect
the power when making resistance or diode tests.
6.
ALWAYS turn off power and disconnect test leads before opening the
covers to replace the fuse or battery.
7.
NEVER operate the meter unless the back cover is in place and fastened
securely.
8.
If the equipment is used in a manner not specified by the manufacturer,
the protection provided by the equipment may be impaired.
Input Protection Limits
Maximum Input
600V AC and DC
200mA DC
10A DC (for 15 seconds max.
every 15 minutes)
500V DC/AC
4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents