SPECIFICATIONS
Function
Range
Capacitance
2nF
20nF
200nF
2µF
20µF
Frequency
20kHz
Sensitivity: 200mVac RMS to 10Vac RMS
Temperature
0 to 32°F
32 to 750°F
760 to 1800°F
NOTE: Accuracy specifications consist of two elements:
• (% reading) – This is the accuracy of the measurement circuit.
• (+ digits) – This is the accuracy of the analog to digital converter.
NOTE: Accuracy is stated at 64
75% RH ambient MultiMeter conditions.
Diode Test
Continuity Check
Temperature sensor
Input Impedance
Display
Overrange indication
Polarity
Measurement Rate
Low Battery Indication
Resolution Accuracy
±(4.0% reading + 3 digits)
1pF
10pF
0.1nF
1nF
10nF
±(1.5% reading + 10 digits)
10Hz
±(5.0% reading + 5 digits)
1°F
±(1.0% reading + 3 digits)
±(2.0% reading + 3 digits)
o
o
F to 82
F (18
Test current of approximately 1mA, open circuit
voltage 2.8V DC typical
Audible signal will sound if the resistance is
less than approximately 40Ω, open circuit
voltage 2.8V DC typical
Type K temperature probe
10MΩ (VDC and VAC)
2000 count LCD
"1" is displayed
Automatic (no indication for positive polarity);
Minus (-) sign for negative polarity.
0.4 seconds, nominal
"
" is displayed if battery voltage drops
below operating voltage
7
o
o
C to 28
C) and less than

Advertisement

Table of Contents
loading

Table of Contents