Toshiba TOSVERT VF-AS1 Instruction Manual page 26

Pg feedback board
Hide thumbs Also See for TOSVERT VF-AS1:
Table of Contents

Advertisement

When using CAB010 (option), conduct terminal processing on the CN8 side, referring to Table 7-2.
CN8
Cannon Plug
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
* Two wires connect to the PGVC and the PGCC of this option.
* There are cases where the wire color may have been changed. Therefore, be sure to confirm on the ter-
minal number of the connector before processing to wire.
* The cut line should be insulated not to contact other wires.
Connect ground terminal of inverter
Remove screw
CN8(Disassemble)
Table7-2 Processing of VFV3 sensor cable
Wire color
A
-
B
-
C
-
D
-
E
-
F
-
G
Blue/White
-
-
N
Black
H
Blue
J
Yellow
K
Yellow/White
L
Green
M
Green/White
N
Brown, Red
Brown/White,
P
Red/White
Connect motor frame ground
Cannon plug
Signal
(PG terminal side process-
Name
-
-
-
-
-
-
NZ
-
-
Z
NA
A
NB
B
COM
Connect to PGCC terminal.
P5
Connect to PGVC terminal.
25
E6581319
Description
ing)
-
-
-
-
-
-
Not used (Cut)
-
Not used (Cut)
Not used (Cut)
Connect to NA terminal.
Connect to A terminal.
Connect to NB terminal.
Connect to B terminal.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tosvert vf-ps1

Table of Contents