QuickSpecs

Technical Specifications

System Unit
Chassis Dimensions
(H x W x D)
Weight
(approximate)
Input Requirements
(per power supply)
Power Supply Output
(per power supply)
Power Specifications To review typical system power ratings use the HP Power Advisor which is available via
Power Supply Output
(per power supply)
System Inlet
Temperature
7.47 x 17.45 x 35.34in (18.96 x 44.33 x 89.97cm)
NOTE: Rack chosen is required to have 1200mm to provide space for cable
management arm at the rear of the chassis and host PDU in the rear of the rack
Maximum
(all hard drives, power
supply, and processor
installed)
Rated Line Voltage
Rated Input Current
Rated Input Frequency 50 to 60 Hz
Rated Input Power
Rated Steady-State
Power
Maximum Peak Power For 1200 W Power Supply:
the online tool located at URL:
www.hp.com/go/proliant-energy-efficient
Rated Steady-State Power
Operating
DA - 14407 Worldwide — Version 9 — December 13, 2013
HP ProLiant SL4545 Generation7 (G7) Server
220lb (99.8kg)
100 to 120 VAC
200 to 240 VAC
For 1200 W Power Supply:
10 A (at 100 VAC),
4.9 A (at 200 VAC)
For 750 W Power Supply:
8.9 A (at 100 VAC),
4.3 A (at 200 VAC)
For 1200 W Power Supply:
930 W (at 100 VAC),
1348 W (at 200 VAC)
For 750 W Power Supply:
857 W (at 100 VAC),
824 W (at 200 VAC)
For 1200 W Power Supply:
800 W (at 100 VAC),
900 W (at 120 VAC),
1200 W (at 200 to 240 VAC)
800 W (at 100 VAC),
900 W (at 120 VAC),
1200 W (at 200 to 240 VAC)
For 750 W Power Supply:
750 W (at 100 to 120 VAC),
750 W (at 200 to 240 VAC)
or www.hp.com/go/hppoweradvisor.
50° to 95° F (10° to 35° C) at sea level with an altitude derating
of 1.8°F per every 1000 ft (1.0°C per every 304.8 m) above sea
level to a maximum of 10,000 ft (3048 m), no direct sustained
sunlight. Maximum rate of change is 18°F/hr (10°C/hr). The
upper limit may be limited by the type and number of options
installed.
System performance may be reduced if operating with a fan
fault or above 86°F (30°C).