Specifications; Electrical And Refrigerant Data - Hoshizaki FD-650MAH-C Instruction Manual

Modular flaker
Hide thumbs Also See for FD-650MAH-C:
Table of Contents

Advertisement

I. Specifications
A. Electrical and Refrigerant Data
The rating label and nameplate provide electrical and refrigerant data. The rating label
can be seen by removing the front panel. The nameplate is located on the rear panel. For
certification marks, see the nameplate.
We reserve the right to make changes in specifications and design without prior notice.
1. FD-650M_H-C
FD-650MAH-C
Model Number
AC Supply Voltage
115/60/1
Compressor
115V 7.9RLA 54.5LRA
Gear Motor
120V 2.3FLA 1/4HP
Fan Motor
115V 1.0FLA 1/15HP
Other
115V
Maximum Fuse Size 20 AMPS
Max. HACR Breaker
20 AMPS
(USA Only)
Max. Circuit Breaker
20 AMPS
(Canada Only)
Minimum Circuit
20 AMPS
Ampacity
Design Pressure
HI-427PSI LO-230PSI
Refrigerant
404A 12.4 OZ.
Single Phase
FD-650MWH-C
115/60/1
115V 5.5RLA 50LRA
120V 2.3FLA 1/4HP
-
0.03A
115V
20 AMPS
20 AMPS
20 AMPS
20 AMPS
HI-427PSI LO-230PSI
404A 15.0 OZ.
FD-650MRH-C
115/60/1
115V 5.5RLA 50LRA
120V 2.3FLA 1/4HP
120V 3A MAX (Fan in URC)
0.03A
115V
20 AMPS
20 AMPS
20 AMPS
20 AMPS
HI-427PSI LO-230PSI
404A
Total Refrigerant Charge
with Hoshizaki Remote
Condenser Unit URC-5F:
4 LB. 1.2 OZ.