Stacking Remote Condenser Unit - Hoshizaki FD-650MAH-C Instruction Manual

Modular flaker
Hide thumbs Also See for FD-650MAH-C:
Table of Contents

Advertisement

3) Install line, neutral, and ground wires from the icemaker fan motor junction box to the
remote condenser unit junction box and make connections. Use wire of an appropriate
gage and outdoor rating.
4) Replace the junction box covers and the louver panel in their correct positions.

7. Stacking Remote Condenser Unit

1) Install the lower remote condenser unit as described earlier in this section.
2) Place the upper remote condenser unit on top of the lower remote condenser unit. See
Fig. 14.
3) Secure the upper remote condenser unit to the lower remote condenser unit with the
4 screws provided.
4) Install refrigerant lines and make electrical connection as described earlier in this
section.
Screws
Fig. 14
25
Upper Remote
Condenser Unit
Screws
Lower Remote
Condenser Unit

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fd-650mwh-cFd-650mrh-c

Table of Contents