HP ProLiant DL2000 Specification page 21

Hp proliant dl2000 multi node server
Table of Contents

Advertisement

QuickSpecs
Configuration Information - Factory Integrated Models
Step 3: Choose Additional Factory Integratable Options (only one of the following from each
list unless otherwise noted)
HP Storage Controllers
Step 4: Choose Additional Options for Factory Integration
NOTE: For additional options, please refer to the "Core Options" and "Additional Options" section below.
NOTE: Non-Hot-Plug SATA Models: The embedded HP Smart Array B110i SATA RAID
supports RAID 0,1,10 and cold-plug capability with hot-plug form factor drives. Non-
hot-plug form factor hard disk drives are not supported in the DL2000.
NOTE: Hot-Plug SATA Models: A HP Smart Array B110i SATA RAID Hot-Plug Advanced
Pack per server or virtual machine is required for hot-plug SATA using the embedded
B110i SATA RAID controller.
NOTE: Supported controllers vary by configuration. See table below for supported
controllers. For a complete list of HP Storage controllers, please see the Additional
Options section of this QuickSpecs. Only FIO options are mentioned here.
Configuration
4x1U nodes with 8LFF HDD cage (2
HDDs/node max)
4x1U nodes with 16SFF HDD cage (4
HDDs/node max)
4x1U nodes with 24SFF HDD cage (6
HDDs/node max)
2x2U nodes with 8LFF HDD cage (4
HDDs/node max)
2x2U nodes with 16SFF HDD cage (8
HDDs/node max)
2x2U nodes with 24SFF HDD cage (12
HDDs/node max)
HP Smart Array P410/ZM 2-ports Int PCIe x8 FIO SAS Controller
Controller Cable Kits
NOTE: Required Controller Cables for the DL2000. The Controller Cables below connect
to the adapter board and is based on the controller used. (If using a configurator, these
cable kits will automatically be included based on controller selection.) For a complete
list of HP Controller Cable Kits, please see the Additional Options section of this
QuickSpecs. Only FIO options are mentioned here.
HP DL170e G6 Smart Array P410 Controller Cable Kit
NOTE: Supports SAS and SATA drives when using Smart Array P410 Controller.
HP DL170e G6 Smart Array Controller Cable Kit
NOTE: Supports SAS and SATA drives when using any Smart Array Controller other than
the Smart Array P410 Controller.
Optional Upgrades
HP Smart Array Hot Plug Advance Pack for B110i w/1y 24x7 Supp Physical 1 Svr LTU
DA - 13847 North America — Version 31 — December 13, 2013
HP ProLiant DL2000 Multi Node Server
Supported Controllers
Embedded (SATA only) or
P410 (SATA/SAS)
Embedded (SATA only) or
P212 or P410 (SATA/SAS)
Embedded (SATA only) or
P410 (SATA/SAS)
Embedded (SATA only) or
P212, P410 or P812 (SATA/SAS)
P410 or P812 (SATA/SAS)
P410 or P812 (SATA/SAS) and
SAS Expander
462860-B21
612206-B21
612207-B21
TC421A
Page 21

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents