QuickSpecs
Technical Specifications
Input Requirements
(per power supply)
BTU Rating
Power Supply Output
(per power supply)
System Inlet Temperature Operating
Relative Humidity
(non-condensing)
Altitude
Acoustic Noise
DA - 14434 North America — Version 9 — October 4, 2013
Minimum
(one hard drive, power
supply, and processor
installed)
Rated Line Voltage
Rated Input Current
Rated Input Frequency
Rated Input Power
Maximum
Rated Steady-State Power 350 W (at 100 VAC),
Maximum Peak Power
Non-operating
Operating
Non-operating
Operating
Non-operating
Listed are the declared A-Weighted sound power levels (LWAd) and declared
average bystander position A-Weighted sound pressure levels (LpAm) when
the product is operating in a 23°C ambient environment. Noise emissions were
measured in accordance with ISO 7779 (ECMA 74) and declared in accordance
with ISO 9296 (ECMA 109).
Idle
L WAd
L pAm
Operating
HP StoreEasy 1000 Storage
25.29 lb (11.47 kg)
100 to 240 VAC
7.1 Amps (at 120VAC) to 3.5 Amps (at 240 VAC)
50 to 60 Hz
486 W
460W - 1773 BTU / hr (at 120 VAC), 1715 (at 240
VAC)
350 W (at 200 VAC)
350 W (at 100 VAC),
350 W (at 200 VAC)
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 304.8 m
(1.8°F per every 1000 ft) above sea level to a
maximum of 3048 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change is
10°C/hr (18°F/hr). The upper limit may be limited
by the type and number of options installed.
System performance may be reduced if operating
with a fan fault or above 30°C (86°F).
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
10 to 90% relative humidity (Rh), 28°C (82.4°F)
maximum wet bulb temperature, non-
condensing.
5 to 95% relative humidity (Rh), 38.7°C (101.7°F)
maximum wet bulb temperature, non-
condensing.
3048 m (10,000 ft). This value may be limited by
the type and number of options installed.
Maximum allowable altitude change rate is 457
m/min (1500 ft/min).
9144 m (30,000 ft). Maximum allowable altitude
change rate is 457 m/min (1500 ft/min).
4.3 B
26dB-A