10.1.1 Register Initialization
Figure 45. Default Register Values
After power on, hard reset, or software reset, the register values are initialized as shown in Figure 45.
Figure 46. Diagnostic Codes
The meaning of the Error Register diagnostic codes resulting from power on, hard reset or the Execute
Device Diagnostic command are shown in Figure 46.
R e g i s t e r
E r r o r
S e c t o r C o u n t
S e c t o r N u m b e r
C y l i n d e r L o w
C y l i n d e r H i g h
D e v i c e / H e a d
S t a t u s
A l t e r n a t e S t a t u s
C o d e
0 1 h
N o e r r o r d e t e c t e d
0 2 h
F o r m a t t e r d e v i c e e r r o r
0 3 h
S e c t o r b u f f e r e r r o r
0 4 h
E C C c i r c u i t r y e r r o r
0 5 h
C o n t r o l l e r m i c r o p r o c e s s o r e r r o r
8 x h
D e v i c e 1 f a i l e d
D e f a u l t V a l u e
D i a g n o s t i c C o d e
0 1 h
0 1 h
0 0 h
0 0 h
A 0 h
5 0 h
5 0 h
D e s c r i p t i o n
General Operation Descriptions
69