Single Hdd Test Condition - Hitachi C4K60 - Travelstar Slim - Hard Drive Specifications

Specifications
Hide thumbs Also See for C4K60 - Travelstar Slim - Hard Drive:
Table of Contents

Advertisement

4.2.2. Single HDD Test Condition

To optimize the performance, keep the following instructions.
1) For the Single HDD test, HDD should be placed on an ABS-sheet. HDD should be place with
no movement by external force min. 0.25N for X axis and Y-axis directions.
2) Don't place HDD on a soft sponge sheet or hard surface at HDD test. If the HDD is placed on
the soft sponge sheet or slippery hard desk surface, the HDD has unstable conditions such as HDD
self-vibration at seek operations or spindle motor rotation. It may cause performance reduction or
some errors. Also, HDD floating by tension of I/F cabling may cause the similar symptom. The HDD
should be placed without any floating. Don't test the HDD under these unstable conditions.
3) If the HDD cannot be fixed by the required holding torque above item 1), put a body weight on the
HDD as shown in Figure 4-3. The body weight is provided for preventing the HDD movement or HDD
floating by tension of I/F cabling.
(10)
K6610170
Rev.2
Dec 22, 2004
(70)
ABS-Sheet
Figure 4.3 Single HDD Test Condition
(80)
- 21 -
Weight:
( ‚ • = 0.42kg,I=4.2 ‚ ˜ 1 0-6kgm2)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents