Operation
CAUTION: If you need to
continuously reset the heater,
unplug the unit and call customer
service at 1-888-346-7539.

Maintenance

  WARNING: Disconnect power
before attempting any main-
tenance or cleaning to reduce
the risk of fire, electric shock or
damage to persons.
!
NOTE: The fireplace should
not be operated with an accumu-
lation of dust or dirt on or in the
unit, as this can cause a build up
of heat and eventual damage.
For this reason the heater must
be inspected regularly, depending
upon conditions and at least at
yearly intervals.
Bulb Replacement
The bulbs are located behind the
back panel.
To gain access to the bulbs:
1. Remove the silver screw that
secures the access panel to
the firebox as indicated in
Figure 2.
2. Remove and slide out panel.
3. Remove the defective lamp
by unscrewing it as shown in
Figure 3.
4. Replace with a 60 Watt E12
clear chandelier or candela-
bra. Take care not to over-
tighten the bulb.
5. Refit the access panel and
secure with the screw re-
moved in step 1.
!
NOTE: To remove the firebox
insert prior to repair, remove the
five black screws at the back of
the firebox as shown in Figure 2
and slide it out to the front.
Helpful Hints: It is a good idea to
replace all light bulbs at one time
if they are close to the end of their
rated life. Group replacement will
reduce the number of times you