Camera Browser Interface
example, when connections are initiated by a controlling
system such as the Bosch Video Client or the Bosch Video
Management System. The camera connects to all remote
stations protected by the same general password. To define a
general password:
1.
2.
3.
4.
Setting destination 10 to the IP-address 0.0.0.0 overrides its
function as the tenth address to try.
12.1.5

Video transmission

If the device is operated behind a firewall, select TCP (HTTP
port) as the transfer protocol. For use in a local network, select
UDP.
To enable multicast operation, select the UDP option for the
Video transmission parameter here and on the Network page.
Note:
In the event of an alarm, a larger network bandwidth is
sometimes required for additional video streams (if multicast
operation is not possible).
12.1.6

Remote port

Select an appropriate browser port depending on the network
configuration. The ports for HTTPS connections are only
available if the On option in SSL encryption is selected.
12.1.7

Video output

If a decoder device is used, select the analog video output to
which the signal should be switched. If the destination device is
unknown, select the First available option. This places the
image on the first video output with no signal.
The connected monitor only displays images when an alarm is
triggered.
Bosch Security Systems
Select 10 in the Number of destination IP address list
box.
Enter 0.0.0.0 in the Destination IP address field.
Enter the password in the Destination password field.
Set the user password of all the remote stations to be
accessed using this password.
Software manual
Alarm | en
AM18-Q0605 | v5.0 | 2011.07