LOCATION 164
SMS 1 FORMAT (1 segment)
The communicator format used to transmit to the SMS 1 report destination from the NX-7002
GPRS module. Consult the instructions for your central station receiver to determine which
format is compatible. SIA reporting over SMS can be set to one of three modes:
DATA
0
1
2
If "0" (Separate Events) is selected, messages are sent using the syntax:
>aaaaaa eennn [eennn ...].
For example, >123456 BA001
If "1" (Combined Events) is selected, messages are sent using the syntax:
>aaaaaa eennn [eennn ...] [/aaaaaa eennn [eennn ...]...] .
For example, >123456 BA001/987654 YT000/345678 TA030
If "2" (Area Modifier) is selected, messages are sent using the syntax:
>aaaaaa eennn[/Rin] [eennn[/Rin] ...].
For example, > 987654 BA001/Ri1 BA003/Ri1 YT000 TA030/Ri3.
Syntax Description :
>
aaaaaa
ee
nnn
Rin
.
/
[X]
[X ...]
NX-7002 Installation manual
FORMAT
SIA Separate Events
SIA Combined Events
SIA with Area Modifier
The message opening character.
A six-digit account code.
A two-digit SIA code.
A three-digit number, e.g. zone number.
Area modifier, 'Ri' is literal, n is the area or partition number.
The message closing character.
Separator
X is optional
X is optional and may be repeated one or more times.