Electrical Requirements
Wire Size
Use ONLY wiring size recommended for single outlet branch circuit.
Use ONLY type and size fuse or HACR circuit breaker indicated on unit's rating plate (See sample on next page). Proper current
Fuse/Circuit Breaker
protection to the unit is the responsibility of the owner.
Unit MUST be grounded from branch circuit to unit, or through separate ground wire provided on permanently connected units.
Grounding
Be sure that branch circuit or general purpose outlet is grounded.
Use recommended wire size given in tables and install a single branch circuit. All wiring must comply with local and national
Wire Sizing
codes. NOTE: Use copper conductors only.
Note: All field wiring must comply with NEC and local codes. It is the responsibility of the installer to insure that the electrical codes are met.
Sample Nameplate
Electric shock hazard.
Turn OFF electric power before service or installation.
All electrical connections and wiring MUST be installed by a qualified electrician and
conform to the National Electrical Code and all local codes which have jurisdiction.
Failure to do so can result in property damage, personal injury and/or death.
All 208/230v chassis must be hard wired with properly sized breaker. See nameplate for specific chassis electri-
cal requirements. See figure 8 for unit wiring and wall thermostat wiring. See page 7 for wire size. Use HACR
type breakers to avoid nuisance trips. All field wiring must be done in accordance with NEC and local codes.