GE VERTICAL ZONELINE 2010 Catalog page 11

2010 vertical zoneline/zoneline/built-in models
Hide thumbs Also See for VERTICAL ZONELINE 2010:

Advertisement

Zoneline units
Chaseway
Power cord and junction box
not included with sub-base.
Chaseway
* A-B Series: Zoneline units built before 1987 – Zoneline I, II, III, and IV; AZC Series: Zoneline units built from 1987 to 1992 – includes AZR Series – Zoneline 1000, 2000, 2500, 2700, 3000,
4000, 5000; AZ Series: Zoneline units built after 1992 – Zoneline 2100, 3100, 2600, 5100 / Zoneline 2200, 3200, 5200 / Zoneline 2500, 3500, 5500 / Zoneline 2800, 2900, 3800, 3900, 4100,
5800, 6100, 7500, 8500.
**RAK204U May be used with AZC and AZ 2100, 3100, 2600 and 5100.
†The power connection kit determines the heater wattage and current requirements when it is plugged into the Zoneline unit. NOTE: 7,000 BTU models do not have 5,000-watt heaters.
RAK204 (AZ Series*—2200, 2500, 3200 and 3500 only)
Standard Sub-Bases WITHOUT power cord included
The RAK204 sub-base is made of heavy-gauge steel to provide support of the wall case.
It has full base enclosure with breakaway side channels, simple connection to wall case
and 4-point leveling legs. The sub-base will adapt to service conduit, circuit breakers
and receptacles up to 30 amps. It may also be used as a non-electrical sub-base to
provide support for the unit.
Kit No.
Sub-Base
RAK204U**
Standard
RAK204D20
Sub-Base 230/208V
RAK204D30
Sub-Base 230/208V
RAK204E15
Sub-Base 265/277V
RAK204E20
Sub-Base 265/277V
RAK204E30
Sub-Base 265/277V
RAK204 (AZ Series*—2800, 2900, 3800, 3900, 4100, 5200, 5500, 5800
and 6100 only)
Standard Sub-Bases WITH power cord included
The RAK204 sub-base is made of heavy-gauge steel to provide support of the wall case.
It has full base enclosure with breakaway side channels, simple connection to wall case and 4-point
leveling legs. The sub-base will adapt to service conduit, circuit breakers and receptacles up to 30
amps. It may also be used as a non-electrical sub-base to provide support for the unit.
Kit No.
Sub-Base
RAK204D15P Sub-Base 230/208V
RAK204D20P Sub-Base 230/208V
RAK204D30P Sub-Base 230/208V
RAK205CW
(AZ Series*—2200, 2500, 2800, 2900, 3200, 3500, 3800, 3900, 4100,
5200, 5500, 5800 and 6100 only)
Chaseway
Chaseway for wiring containment between junction box on
chassis and RAK204U sub-base.
RAK5157/5207/5307
(AZ Series*—2800, 2900, 3800, 3900, 4100, 5500, 5800, 6100)
265/277-Volt Universal Power Supply Kit
• 9-pin connector with three 7" 12-gauge conductor wires
Kit No.
Volts
Heater Wattage
RAK5157
265/277
2.4 kw
RAK5207
265/277
3.4 kw
RAK5307
265/277
4.8 kw
Circuit
Ampacity
Chaseway
N/A
Not Included
15 & 20
Included
30
Included
15
Included
20
Included
30
Included
Circuit
Ampacity
Chaseway
15
Included
20
Included
30
Included
Circuit
Ampacity
15
20
30
Power Cord
Not Included
Not Included
Not Included
Not Included
Not Included
Not Included
Power Cord
Included
Included
Included
11

Advertisement

loading