Maytag MDG30V Installation Manual page 28

30 lb. single pocket
Table of Contents

Advertisement

2. Technical Gas Data
a. Gas Specifications
Manifold Pressure*
In-Line Pressure
Shaded areas are stated in metric equivalents
*Measured at outlet side of gas valve pressure tap when gas valve is on.
b. Gas Connections
Inlet connection ------------- 1/2" N.P.T.
Inlet supply size ------------- 1/2" N.P.T. (minimum)
Heat input (per dryer) ------ 100,000 btu/hr (25,200 kcal/hr)
1)
Natural Gas
Regulation is controlled by the dryer's gas valve's internal regulator. Incoming supply pressure
must be consistent between a minimum of 6.0 inches (14.92 mb) and a maximum of 12.0 inches
(29.9 mb) water column (W.C.) pressure.
2) Liquid Propane (L.P.) Gas
Dryers made for use with L.P. gas have the gas valve's internal pressure regulator blocked open so
that the gas pressure must be regulated upstream of the dryer. The pressure measured at each
gas valve pressure tap must be a consistent 10.5 inches (26.1 mb) water column. There is no
regulator or regulation provided in an L.P. dryer. The pressure must be regulated at the source
(L.P. tank) or an external regulator must be added to each dryer.
BTU
MODEL
Per Hour
NUMBER
Rating
MDG30V
100,000
Shaded area is stated in metric equivalent
* Drill Material Size (D.M.S.) equivalents are as follows:
Natural Gas ...................... #29 = 0.1360" (3.4540 mm).
Liquid Propane Gas ......... #46 = 0.810" (2.0574 mm).
TYPE OF GAS
NATURAL
3.5 inches W.C.
6.0 - 12.0 inches W.C.
TYPE OF GAS
Natural
kcal/hr
Rating
Qty.
D.M.S.*
25,200
2
#29
8.7 mb
10.5 inches W.C.
14.92 - 29.9 mb
11.0 inches W.C.
Liquid Propane
Part
Qty.
D.M.S.*
Number
140820
2
#46
24
LIQUID PROPANE
26.1 mb
27.4 mb
Liquid Propane
Conversion Kit
Part
Part Number
Number
140806
883321

Advertisement

Table of Contents
loading