MDG35 / MDG52 / MDG78
Installation Manual
RETAIN THESE
INSTRUCTIONS IN A
SAFE PLACE FOR
FUTURE REFERENCE
Part No. 112204 - 6

Advertisement

Table of Contents
loading

Summary of Contents for Maytag MDG35

  • Page 1 MDG35 / MDG52 / MDG78 Installation Manual RETAIN THESE INSTRUCTIONS IN A SAFE PLACE FOR FUTURE REFERENCE Part No. 112204 - 6...
  • Page 2: Dryer Safety

    – L’installation et l’entretien doivent être assurés par un installateur ou un service d’entretien qualifié ou par le fournisseur de gaz. Maytag Co. 112204 - 6...
  • Page 3 Fuel Gas Code, ANSI Z223.1/NFPA 54 or the Canadian Natural Gas and Propane Installation Code, CSA B149.1. The dryer must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1. 112204 - 6 Maytag Co.
  • Page 4: Table Of Contents

    Table of Contents ______________ Important Information ________________ IMPORTANT: A means of restraint must be used to avoid MDG35 Specifications ..........5 straining of the gas supply when the dryer is moved. An external means of power removal (disconnect device) must be provided by the installer.
  • Page 5: Mdg35 Specifications

    MDG35 Specifications _____________________________________________________________ MAXIMUM CAPACITY (DRY WEIGHT) 35 lb 15.88 kg TUMBLER DIAMETER 30” 76.20 cm 76.20 cm TUMBLER DEPTH 30” TUMBLER VOLUME 12.27 cu ft 347.44 L 0.19 kW TUMBLER / DRIVE MOTOR 1/4 hp BLOWER / FAN MOTOR 1/2 hp 0.37 kW...
  • Page 6: Mdg52 Specifications

    EXHAUST CONNECTION (DIAMETER) 8” 20.32 cm INLET PIPE CONNECTION 1/2” M.N.P.T. Shaded areas are stated in metric equivalents 6/17/13 NOTE: The manufacturer reserves the right to make changes in specifications at any time without notice or obligation. Maytag Co. 112204 - 6...
  • Page 7: Mdg78 Specifications

    EXHAUST CONNECTION (DIAMETER) 8” INLET PIPE CONNECTION 1/2” M.N.P.T. Shaded areas are stated in metric equivalents 10/3/13 NOTE: The manufacturer reserves the right to make changes in specifications at any time without notice or obligation. 112204 - 6 Maytag Co.
  • Page 8: Installation Procedures

    5. Having handle flushed against door, tighten the two stainless Phillips screws. IMPORTANT: The dryer must be installed in a location/ environment, where the ambient temperature remains between 40° F (4.44° C) and 130° F (54.44° C). Maytag Co. 112204 - 6...
  • Page 9: Dryer Enclosure Requirements

    B = 19-inches (48.3 cm) The requirement to allow the door to open completely for the MDG35 is 33-inches (83.8 cm), and the MDG52 and MDG78 are 40-inches (101.6 cm). EXAMPLE: For a bank of four MDG78 dryers, two unrestricted A minimum overhead clearance of 6-inches (15.24 cm)
  • Page 10: Single Dryer Venting

    A = 20 feet (6.10 meters) C = 12 feet (3.66 meters) MDG35 B = 6-inches (15.24 cm) D = 6-inches (15.24 cm) or other obstructions, which will collect lint. When adding MDG52 A = 25 feet (7.62 meters)
  • Page 11: Electrical Information

    MDG52 8-inch (20.32 cm) MDG78 8-inch (20.32 cm) IMPORTANT: Failure to comply with these codes or B = MDG35 12 feet (3.66 meters) MDG52 20 feet (6 meters) ordinances, and/or the requirements stipulated in this MDG78 20 feet (6 meters manual can result in component failure.
  • Page 12: Electrical Connections

    Tighten strain relief screws assuring to leave a 1/2” of slack done by a qualified service technician. in the box. MDG35 L.P. Conversion Kit: 887295 MDG52 L.P. Conversion Kit: 887296 Replace electrical box plate by inserting 3 screws previously MDG78 L.P. Conversion Kit: 887293 removed.
  • Page 13 B149.1, Natural Gas and Propane Installation Code. It is recommended that an ____________________________________________________________ individual manual shutoff valve be installed within 6 feet (1.8 meters) of the dryer. ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ 112204 - 6 Maytag Co.
  • Page 14: Gas Connections

    Orifice Size* Heating Value Pressure Heat Input Pressure Model (Injector) Type Quantity B tu /ft in WC Btu/hr in WC 7.0-13.0 18.74 3.912 MDG35 Natural 1,000 64,000 7.0-13.0 32.24 3.988 MDG52 Natural 1,000 110,000 MDG78 Natural 1,000 7.0-13.0 130,000 38.1 3.734...
  • Page 15: Water Information (Pn Models Only)

    5. Screw coupling on by hand until seated on the supply from freezing. valve. 112204 - 6 Maytag Co.
  • Page 16: Preparation For Operation / Start-Up

    • Check that the vent is connected to the dryer and is the cycle will resume only after the door has been closed exhausted to the outdoors. and any one of the 3 temperature selections is pressed. Maytag Co. 112204 - 6...
  • Page 17: Shutdown Instructions

    Non-Coin Models NOTE: When ordering replacement parts from the Maytag distributor or the Maytag Co. be sure to give them the Microprocessor Controller (Computer) correct model number and serial number so that your parts order can be processed in an expeditious manner.
  • Page 18: Data Label Information

    ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ When contacting Maytag, the information on the data label is required to ensure proper service/parts assistance. The ____________________________________________________________ data label is located at the lower left rear of the dryer behind the back guard. ____________________________________________________________ 1.