Maytag MDG30PCCWW Installation Instructions Manual

Commercial multi-load dryer

Advertisement

Quick Links

Commercial
Multi-Load
Dryers
Models
MDG30MC2
MDG30PC2
MDG30PNA
MDG30MNA
PRODUCT SPECIFICATIONS
• Drive motor: 1/2 H.P. (.373 Kw)
• Air flow: 600 cubic feet (17 cubic meters) per minute.
• Amperage Draw: 9.8 amps (approximate).
• Heat source: 90,000 BTU/Hr. (22,680 kcal/hr.).
• Flush to side wall installation possible, 24" rear clearance suggested for ease of maintenance.
• Tumbler Capacity: 12.3 cu. ft. (.348 cu.m.)
• Tumbler Diameter: 30" (76.2 cm)
• Tumbler Depth: 30" (76.2 cm)
• Door Opening: 21 1/2" Dia. (54.61 cm)
• Weight: Crated: 550 lbs. (250 Kg)
Uncrated: 500 lbs. (227 Kg)
• Gas Inlet 1/2" I.D.
ELECTRICAL REQUIREMENTS
• 120 volts, 60 Hz single phase, (some 240 volts, 50 Hz models available for export).
• Individual branch circuit serving only the dryer is recommended.
• Minimum wire size required, awg. 12 with a 20 amp fuse or comparable circuit breaker. Copper
wire only.
• Dryer must be installed and grounded in accordance with National Electrical Codes and local
codes and ordinances.
COMMERCIAL MULTI LOAD DRYERS - MDG30, MC2, PC2, PNA, and MNA
PRODUCT DIMENSIONS
ELECTRICAL CONN.
GAS INLET
6"
15.2 cm
11 1/2"
29.2 cm
6"
15.2 cm
8"
158.8 cm
20.3 cm
20 1/4"
EXHAUST
51.4 cm
DIAMETER
REAR VIEW
72"
182.9 cm
63"
160 cm
62 1/2"
TOP VIEW
43"
109.2 CM
31 3/8"
79.7 cm
07/02
6-1

Advertisement

Table of Contents
loading

Summary of Contents for Maytag MDG30PCCWW

  • Page 1 Commercial Multi-Load Dryers Models MDG30MC2 MDG30PC2 MDG30PNA MDG30MNA PRODUCT SPECIFICATIONS • Drive motor: 1/2 H.P. (.373 Kw) • Air flow: 600 cubic feet (17 cubic meters) per minute. • Amperage Draw: 9.8 amps (approximate). • Heat source: 90,000 BTU/Hr. (22,680 kcal/hr.). •...
  • Page 2: Exhaust Requirements

    EXHAUST REQUIREMENTS Exhaust duct work should be designed and installed by a qualified professional. Improperly sized duct work will create excessive back pressure which results in slow drying, increased use of energy, and shutdown of the burner by the airflow (sail) switch, burner hi-limit chamber hi-heat protector thermostat. Where possible, it is suggested to provide a separate (single) exhaust duct for each dryer.
  • Page 3: Single Dryer Venting

    SINGLE DRYER VENTING IMPORTANT: For exhaust duct runs over 30 feet a minimum diameter size of 10 inches must be used HORIZONTAL VENTING When horizontal single 8-inch venting is used, the duct work to the outlet cannot exceed 30 feet (refer to Illus. A below).
  • Page 4: Vertical Venting

    VERTICAL VENTING When vertical venting is used minimum duct diameter size is 10 inches (refer to Illus. B below), the duct work from the dryer to the outside outlets cannot exceed 60 feet (refer to Illus. B below). This calculation compensates for the use of a maximum of three (3) elbows including the two (2) elbows creating the 180°...
  • Page 5 MULTIPLE DRYER (Common) VENTING HORIZONTAL VENTING If it is not feasible to provide separate exhaust ducts for each dryer, ducts for individual dryers may be channeled into a common main duct. Each dryer is provided with a back draft damper. The individual ducts should enter the bottom or side of the main duct at an angle not more than 45°...
  • Page 6 Illus. C (refers to the previous page 5-5) shows the minimum cross-section area for horizontal multiple dryer venting. These figures must be increased in proportion if the main duct run from the last dryer to where the exhaust has numerous elbows or is unusually long. IMPORTANT: For extended duct work runs, the cross-section area of the duct can only be increased to an extent.
  • Page 7 IMPORTANT VENTING REMINDERS Duct work size and installation should be done by a qualified professional. 2. The dryer must be exhausted to the outdoors. 3. Duct work should be routed as short as possible to the outdoors with as few elbows as possible. 4.
  • Page 8: Make-Up Air Requirements

    MAKE-UP AIR REQUIREMENTS • Makeup area opening must have 1 square feet for each dryer. • Common makeup air openings are acceptable. IMPORTANT: Makeup air must be provided from a source free of contaminating fumes such as dry cleaning fumes. Make-up air contaminated by dry cleaning solvent fumes will result in irreparable damage to motors and other dryer components.