Maytag MDG30PNHWW Installation Manual

30 lb single pocket / phase 7 / non-coin with fire suppression system

Advertisement

Quick Links

MDG30PNH / MDG30MNV
Installation Manual
30 lb Single Pocket / Phase 7 / Non-Coin
with Fire Suppression System
WARNING: For your safety the information
in this manual must be followed to
minimize the risk of fire or explosion and
to prevent property damage, personal
injury or death.
— Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch;
do not use any phone in your
building.
Clear the room, building or area of
all occupants.
Immediately call your gas supplier
from a neighbor's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the fire department.
— Installation and service must be
performed by a qualified installer, service
agency or the gas supplier.
AVERTISSEMENT: Assurez-vous de bien
suivre les instructions données dans cette
notice pour réduire au minimum le risque
d'incendie ou d'explosion ou pour éviter
tout dommage matériel, toute blessure ou
la mort.
—Ne pas entreposer ni utiliser d'essence
ni d'autres vapeurs ou liquides
inflammables à proximité de cet
appareil ou de tout autre appareil.
—QUE FAIRE SI VOUS SENTEZ UNE
ODEUR DE GAZ:
Ne pas tenter d'allumer d'appareils.
Ne touchez à aucun interrupteur. Ne
pas vous servir des téléphones se
trouvant dans le bâtiment.
Évacuez la pièce, le bâtiment ou la
zone.
Appelez immédiatement votre
fournisseur de gaz depuis un voisin.
Suivez les instructions du fournisseur.
Si vous ne pouvez rejoindre le
fournisseur de gaz, appelez le service
des incendies.
—L'installation et l'entretien doivent être
assurés par un installateur ou un
service d'entretien qualifié ou par le
fournisseur de gaz.
RETAIN THESE
INSTRUCTIONS IN A
SAFE PLACE FOR
FUTURE REFERENCE
Part No. 113307-7

Advertisement

Table of Contents
loading

Summary of Contents for Maytag MDG30PNHWW

  • Page 1 MDG30PNH / MDG30MNV Installation Manual 30 lb Single Pocket / Phase 7 / Non-Coin with Fire Suppression System WARNING: For your safety the information in this manual must be followed to minimize the risk of fire or explosion and to prevent property damage, personal injury or death.
  • Page 2 These instructions must be posted in a prominent location near the dryer. POUR VOTRE SÉCURITÉ Ne pas entreposer ni utiliser d’essence ni d’autres vapeurs ou liquides inflammables à proximité de cet appareil ou de tout autre appareil. Important Maytag Co. Benton Harbor, MI 1-800-662-3587...
  • Page 3: For Your Safety

    YOU MUST DISCONNECT AND LOCKOUT THE ELECTRIC SUPPLY AND THE GAS SUPPLY OR THE STEAM SUPPLY BEFORE ANY COVERS OR GUARDS ARE REMOVED FROM THE MACHINE TO ALLOW ACCESS FOR CLEANING, ADJUSTING, INSTALLATION, OR TESTING OF ANY EQUIPMENT PER OSHA (Occupational Safety and Health Administration) STANDARDS.
  • Page 4 WARNING The dryer must never be operated with any of the back guards, outer tops, or service panels removed. PERSONAL INJURY OR FIRE COULD RESULT. WARNING DRYER MUST NEVER BE OPERATED WITHOUT THE LINT FILTER/SCREEN IN PLACE, EVEN IF AN EXTERNAL LINT COLLECTION SYSTEM IS USED. IMPORTANT PLEASE OBSERVE ALL SAFETY PRECAUTIONS displayed on the equipment and/or specified in the installation manual included with the dryer.
  • Page 5: Table Of Contents

    Table of Contents SECTION I SAFETY PRECAUTIONS ... 2 SECTION II SPECIFICATIONS ... 4 SECTION III INSTALLATION PROCEDURES ... 6 A. Unpacking/Setting Up ... 6 B. Location Requirements ... 6 C. Dryer Enclosure Requirements ... 7 D. Fresh Air Supply Requirements ... 8 E.
  • Page 6: Section I

    4. Installation and service must be performed by a qualified installer, service agency, or gas supplier. 5. Dryers must be exhausted to the outdoors. 6. Although Maytag produces a very versatile dryer, there are some articles that, due to fabric composition or cleaning method, should not be dried in it.
  • Page 7 THE GAS SUPPLY OR THE STEAM SUPPLY BEFORE ANY COVERS OR GUARDS ARE REMOVED FROM THE MACHINE TO ALLOW ACCESS FOR CLEANING, ADJUSTING, INSTALLATION, OR TESTING OF ANY EQUIPMENT PER OSHA (Occupational Safety and Health Administration) STANDARDS. 113307 - 7 Maytag Co.
  • Page 8: Specifications

    25-5/8” 1/2 hp 21-1/2” 12.5 cu ft 120v 1ø 2w 60 Hz 534 lbs 571 lbs 100,000 Btu/hr 460 cfm Maytag Co. 13.6 kg 83.2 cm 65.1 cm 0.373 kW 54.61 cm 0.354 cu m 12/26 30/32 3/4” - 11.5 NH...
  • Page 9 Specifications NOTE: The manufacturer reserves the right to make changes in specifications at any time without notice or obligation. 113307 - 7 Maytag Co.
  • Page 10: Installation Procedures

    IMPORTANT: “The dryer must be installed on noncombustible floors only.” 2. The dryer must not be installed or stored in an area where it will be exposed to water and/or weather. 3. The dryer is for use in noncombustible locations. SECTION III Maytag Co. 113307 - 7...
  • Page 11: Dryer Enclosure Requirements

    X = 12-inch (30.48 cm) minimum, 24-inches (60.96 cm) is suggested for ease of maintenance. Not applicable. A minimum of 12-inches (30.48 cm) above the dryer’s outer top; except along the front of the dryer, which may be closed if desired. 113307 - 7 Maytag Co.
  • Page 12: Fresh Air Supply Requirements

    NOTE: Component failure due to dry cleaning solvent fumes will VOID THE WARRANTY. [6.4516 cm B = 18-inches (45.72 cm) Maytag Co. ] per 1,000 Btu [251.9958 113307 - 7...
  • Page 13: Exhaust Requirements

    NOTE: As per the National Fuel Gas Code, “Exhaust ducts for Type 2 clothes dryers shall be constructed of sheet metal or other noncombustible material. Such ducts shall be equivalent in strength and corrosion resistance to ducts made of galvanized sheet steel not less than 26 gauge (0.0195-inches [0.50 mm]) thick.” 113307 - 7 Maytag Co.
  • Page 14: Single Dryer Venting

    NOTE 1 Opening must be 2-inches (5.08 cm) larger than the duct (all the way around). The duct must be centered within this opening. NOTE 2 Distance should be 2 times the diameter of the duct to the nearest obstruction. Maytag Co. 113307 - 7...
  • Page 15 NOTE 1 Opening must be 2-inches (5.08 cm) larger than the duct (all the way around). The duct must be centered within this opening. NOTE 2 Distance should be 2 times the diameter of the duct to the nearest obstruction. 113307 - 7 SQ IN SQ CM 1058 35.56 30.48 25.4 Maytag Co. 20.32...
  • Page 16: Electrical Information

    VOID THE WARRANTY. NOTE: Component failure due to improper voltage application will VOID THE WARRANTY. NOTE: The manufacturer reserves the right to make changes in specifications at any time without notice or obligation. Maytag Co. 113307 - 7...
  • Page 17 In both cases, a strain relief must be installed where the wiring enters the dryer. IMPORTANT: A separate protected circuit must be provided to each dryer. 113307 - 7 APPROX. WIRE AMP DRAW SERVICE 60 Hz 50 Hz Maytag Co. CIRCUIT BREAKER 6/25/08...
  • Page 18 Single-Phase Electrical Lead Connections White or Red Black Green Neutral Positive Ground or L2 FOR 110V APPLICATIONS FOR 208-240V APPLICATIONS A ground lug is provided in the rear electrical box to connect your service ground. Maytag Co. 113307 - 7...
  • Page 19: Gas Information

    The adjustment or conversion of dryers in the field for elevations over 2,000 feet (610 meters) is made by changing each burner orifice. If this conversion is necessary, contact the dealer who sold the dryer or contact the Maytag Co. 113307 - 7...
  • Page 20 Liquid Propane Gas ... #46 = 0.810” (2.0574 mm). TYPE OF GAS NATURAL 8.7 mb TYPE OF GAS Natural Liquid Propane Part Qty. D.M.S.* Number 140820 Maytag Co. LIQUID PROPANE 26.1 mb 10.5 inches W.C. 27.4 mb 11.0 inches W.C. Liquid Propane Conversion Kit Part Part Number Number...
  • Page 21 (19.05 mm) pipe gas loop be installed in the supply line servicing a bank of dryers. An in-line pressure regulator must be installed in the gas supply line (header) if the (natural) gas pressure exceeds 12.0 inches (29.9 mb) of water column (W.C.) pressure. (Refer to the illustrations below.) 113307 - 7 Maytag Co.
  • Page 22: Preparation For Operation/Start-Up

    9. Rotate the basket (tumbler/drum) by hand to be sure it moves freely. 10. Check basket (tumbler) bearing setscrews to ensure that they are ALL tight. 11. Check vent is connected to the dryer and is exhausted to the outdoors. Maytag Co. 113307 - 7...
  • Page 23: Preoperational Tests

    The heating unit should not activate (wait 30-seconds). If heat does activate, make the necessary adjustments to the sail switch. 5. Make a complete operational check of ALL operating controls. 113307 - 7 Maytag Co.
  • Page 24: Preoperational Instructions

    DUAL TIMER DRYERS 1. Turn drying timer knob for a time of 20 minutes. 2. Select “High Temp.” 3. Push “Push to Start” button. 4. To stop dryer, open the main door. BASKET (TUMBLER) COATING Maytag Co. 113307 - 7...
  • Page 25: Shutdown Instructions

    2. Discontinue the heat supply: GAS MODELS – discontinue the gas supply. a. SHUT OFF external gas supply shutoff valve. b. SHUT OFF internal gas supply shutoff valve located in the gas valve burner area. 113307 - 7 10.2 Maytag Co.
  • Page 26: Service/Parts Information

    Replacement parts should be purchased from the dealer from whom the Maytag equipment was purchased. If the dealer cannot be contacted or is unknown, contact the Maytag Co. for a dealer in your area. NOTE: When ordering replacement parts from the Maytag dealer or the Maytag Co. be sure to give the correct model number and serial number so that the parts order can be processed in an expeditious manner.
  • Page 27: Warranty Information

    NOTE: Be sure to include the installation date when returning the warranty card(s). B. WARRANTY For a copy of the manufacturer’s commercial warranty covering your particular dryer(s), contact the Maytag dealer from whom you purchased the equipment and request a dryer warranty form. If the dealer cannot be contacted or is unknown, warranty information can be obtained from the Maytag Co.
  • Page 28: Routine Maintenance

    Maximum operating efficiency is dependent upon proper air circulation. The accumulation of lint can restrict this airflow. If the guidelines in this section are met, a Maytag dryer will provide many years of efficient, trouble free, and most importantly safe operation.
  • Page 29: Adjustments

    DO NOT have a grease fitting. Provisions are made in the bearing housing for the addition of a grease fitting which can be obtained elsewhere, or from the Maytag dealer by ordering kit P/N 882159 (includes two [2] fittings).
  • Page 30: Data Label Information

    DATA LABEL INFORMATION When contacting the Maytag dealer, certain information is required to ensure proper service/parts information. This information is on the dryer data label affixed to the left side panel area behind the top control (access) door. When contacting the Maytag Co., please have the model number and serial number available.
  • Page 31: Procedure For Functional Check Of Replacement Components

    Start the drying cycle by pressing any of the preset cycles in letters A-F. c. Verify that the applicable indicator lights on the back side of the microprocessor controller (computer) board are lit. (Refer to the illustration below.) 113307 - 7 SECTION VIII Maytag Co.
  • Page 32 “LOCKOUT” (a red L.E.D. diagnostic indicator will flash). An unlit red L.E.D. diagnostic indicator indicates normal operation. A lit green L.E.D. diagnostic indicator indicates dryer controller is calling for heat and that ALL interlocks have been satisfied. Maytag Co. 113307 - 7...
  • Page 33: Fire Suppression System

    IMPORTANT: It is the installer’s or owner’s responsibility to see that the necessary or required water, water pressure, pipe size, or connections are provided. The manufacturer assumes no responsibility if the fire suppression system is not connected, installed, or maintained properly. 113307 - 7 SECTION IX Maytag Co.
  • Page 34 N.P.T. assembly. The two (2) thread designs are not compatible. IMPORTANT: Flexible supply line/coupling must be used. Solenoid valve failure due to hard plumbing connections WILL VOID WARRANTY. It is recommended that a filter or strainer be installed in the water supply line. Maytag Co. 113307 - 7...
  • Page 35 If the rear area of the dryer or the water supply is located in an area where it will be exposed to cold/freezing temperatures, provisions must be made to protect these water lines from freezing. WARNING: If the water in the supply line or water solenoid valve freezes, the fire suppression system will be INOPERATIVE!! 113307 - 7 Maytag Co.
  • Page 36 Part No. 113307 7 - 06/26/08 - 0...

This manual is also suitable for:

Mdg30mnvww

Table of Contents