Maytag MDG30V Installation Manual page 26

30 lb. single pocket
Table of Contents

Advertisement

ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)
IMPORTANT: 208 VAC AND 240 VAC ARE NOT THE SAME. When ordering,
NOTES: A.
When fuses are used they must be dual element, time delay, current limiting,
class RK1 or RK5 ONLY. Calculate/determine correct fuse value, by
applying either local and/or National Electrical Codes to listed appliance amp
draw data.
B.
Circuit breakers are thermal-magnetic (industrial) motor curve type ONLY.
For others, calculate/verify correct breaker size according
to appliance amp draw rating and type of breaker used.
C.
Circuit breakers for 3-phase (3Ø) dryers must be 3-pole type.
SERVICE
VOLTAGE
120 (60 Hz)
208 (60 Hz)
240 (60 Hz)
208 (60 Hz)
240 (60 Hz)
380-400 (50 Hz)
416 (50 Hz)
460/480 (60 Hz)
IMPORTANT: Figures shown are for non-reversing models only. For reversing models contact the
factory.
IMPORTANT: The dryer must be connected to the electric supply shown on the data label that is
affixed to the left side panel area behind the top control (access) door. In the case of
208 VAC or 240 VAC, the supply voltage must match the electric service
specifications of the data label exactly.
IMPORTANT: The wire size must be properly sized to handle the related current.
WARNING: 208 VAC AND 240 VAC ARE NOT THE SAME. Any damage done to dryer
components due to improper voltage connections will automatically VOID THE
WARRANTY.
NOTE: Manufacturer reserves the right to make changes in specifications at any time without notice
or obligation.
M DG30V (GAS)
specify exact voltage.
WIRE
PHASE
SERVICE
2
2
2
3/4
3/4
3/4
3/4
3/4
APPROX.
AMP DRAW
60 Hz
50 Hz
9.6
---
5.8
---
5.3
4.4
3.0
---
3.2
4.0
---
2.2
---
2.3
2.1
---
22
CIRCUIT
BREAKER
15
15
15
15
15
15
15
15