2. Technical Gas Data
a. Gas Specifications
Manifold Pressure*
In-Line Pressure
Shaded areas are stated in metric equivalents
* Measured at outlet side of gas valve pressure tap when gas valve is on.
b. Gas Connections
Inlet connection ..................... 1/2" N.P.T.
Inlet supply size ..................... 1/2" Diameter Pipe (minimum)
Btu/hr input (per dryer) ......... 90,000 (22,680 kcal/hr)
1) Natural Gas
Regulation is controlled by the dryer's gas valve's internal regulator. Incoming supply pressure
must be consistent between a minimum of 6.0 inches (14.92 mb) and a maximum of 12.0 inches
(29.9 mb) of water column (W.C.) pressure.
2) Liquid Propane (L.P.) Gas
Dryers made for use with L.P. gas have the gas valve's internal pressure regulator blocked open so
that the gas pressure must be regulated upstream of the dryer. The pressure measured at each
gas valve pressure tap must be a consistent 10.5 inches (26.1 mb) of water column. There is no
regulator or regulation provided in an L.P. dryer. The water column pressure must be regulated at
the source (L.P. tank) or an external regulator must be added to each dryer.
Btu/hour
kcal/hr
Rating
Rating
90,000
22,680
Shaded areas are stated in metric equivalents
* Drill Measurement Size (D.M.S.) equivalents are as follows:
Natural Gas ............................. #30 = 0.1285" (3.2639 mm).
Liquid Propane Gas ................. #46 = 0.0810" (2.06 mm).
113201 - 7
TYPE OF GAS
NATURAL
3.5 inches W.C.
6.0 - 12.0 inches W.C. 14.92 - 29.9 mb
TYPE OF GAS
Natural
Qty.
D.M.S.*
Part No.
2
#30
140819
8.7 mb
Liquid Propane
Qty.
D.M.S.*
2
#46
Maytag Co.
LIQUID PROPANE
10.5 inches W.C.
26.1 mb
27.4 mb
11.0 inches W.C.
Liquid
Propane
Conversion Kit
Part Number
Part No.
140806
874050