Adjustments; Lubrication - Maytag MD-170PTVW Installation Manual

Phase 7 / non-coin / dual timer with s.a.f.e. system
Table of Contents

Advertisement

B. ADJUSTMENTS
7 DAYS AFTER INSTALLATION AND EVERY 6 MONTHS THEREAFTER
Inspect bolts, nuts, screws, setscrews, grounding connections, and nonpermanent gas connections (unions, shutoff
valves, and orifices). Motor and drive belts should be examined. Cracked or seriously frayed belts should be
replaced. Tighten loose V-belts when necessary. Complete operational check of controls and valves. Complete
operational check of ALL safety devices (door switch, lint drawer switch, sail switch, burner, and hi-limit
thermostats).
NOTE: Squirrel cage type fan (impellor) on the blower motor must be inspected and cleaned every 6
months.
C. LUBRICATION
The motor bearings and under normal/most conditions the basket (tumbler) and idler bearings are permanently
lubricated. It is physically possible to relubricate the basket (tumbler) and idler bearings if you choose to do so
even though this practice is not necessary. Use Shell Alvania #2 or its equivalent. The basket (tumbler) and idler
bearings used in the dryer DO NOT have a grease fitting. Provisions are made in the bearing housing for the
addition of a grease fitting, which can be obtained elsewhere, or from the Maytag dealer by ordering kit part
number 882159 (basket [tumbler] ONLY), which includes two (2) fittings.
113395 - 6
Maytag Co.
39

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mdg-120pvv

Table of Contents