CAUTION: This dryer produces combustible lint and must be exhausted to the outdoors. Every 6
months, inspect the exhaust ducting and remove any lint buildup.
IMPORTANT: The dryer must be installed in a location/environment, which the ambient
temperature remains between 40° F (4.44° C) and 130° F (54.44° C).
B. UNPACKING/SETTING UP
Remove protective shipping material (i.e., plastic wrap, and/or optional shipping box) from dryer.
IMPORTANT: The dryer must be transported and handled in an upright position at ALL times.
The dryer can be moved to its final location while still attached to the skid or with the skid removed. To remove
skid from the dryer, locate and remove the four (4) lag bolts securing the base of the dryer to the wooden skid.
Two (2) are located at the rear base (remove the back panel for access) and two (2) are located in the bottom
of the lint chamber. To remove the two (2) lag bolts located in the lint chamber area, remove the lint drawer and
the three (3) Phillips head screws securing lint door in place.
1. Leveling Dryer
To level dryer, place 4-inch (10.16 cm) square metal shims (refer to illustration above) or other suitable
material under the base pads. It is suggested that the dryer be tilted slightly to the rear.