NOTE: DO NOT ATTEMPT TO SERVICE THE RANGE
YOURSELF. CONTACT YOUR LOCAL AGA DISTRIBUTOR
STATING THE MODEL AND SERIAL NUMBER TOGETHER
WITH YOUR NAME AND ADDRESS

REPLACEMENT PARTS

In the event of a component failure which requires
replacement, contact your local Aga Distributor who will
advise and supply the necessary replacement.
Expendable components that will require replacing at some
time or other are listed as follows:-
Description
1.
Pilot Thermocouple
2.
Main Burner
3a.
Pilot Burner Assembly N.G.
3b.
Pilot Burner Assembly L.P.G.
4.
Combination Gas Valve
5a.
Pressure Regulator N.G.
5b.
Pressure Regulator L.P.G.
6.
Combustion Chamber Door Seal

TECHNICAL SPECIFICATION

Models
GC and GE - Open Vent/GC and GE - Direct Vent
Gas Type
Range Model
Main Burner
Injector
Pilot Burner Injector
Combination
Gas Valve
Bypass Screw
Gas Burner
Pressure
Combination
Gas Valve
Pilot Assembly
6
Natural Gas
L.P.G.
GC/GE
GC/GE
400
180
N35
L23
1.00mm
0.60mm
or
1.20mm
0.80mm
4.0
10.0
inch w.c.
inch w.c.
S.I.T. EUROSIT
JOHNSONS
or

Advertisement