CONNECTING THE TISS SYSTEM

Description: The TISS (Tube Integrity Safety System) is designed to shut the main burner off in the event that a
burnout occurs in the first 10ft. section of firing tube. Note: When replacing the firing tube a new TISS wire assembly
PN 44176010 must also be installed.
Instructions:
1. Make sure that the gap between the burner box and end of reflector is 3" and the reflector is securely
attached to the reflector support bracket. Make adjustments if necessary.
Step 1
2. Un-roll the TISS wire assembly from the spool. Be careful not to kink the wires.