Power Cord And Strain Relief Installation - GE JBS07 Owner's Manual And Installation Instructions

Electric coil & radiant ranges
Table of Contents

Advertisement

Installation instructions
POWER CORD AND STRAIN
RELIEF iNSTALLATiON
[]
Remove
the wire
cover
(on the lower
back of the range)
by removing
two
(2)
screws
using
a 1/4" nut driver.
Do not discard these
screws.
[]
Back of range
Wire cover
Remove
the knockout
ring (13/8") located
on bracket
directly
below
the terminal
block.
To remove
the knockout,
use a
pair of pliers
to bend the knockout
ring
away
from
the bracket
and twist
until
ring
is removed.
_
erminal
block
(appearance
may vary)
Knockout
ring
ring removed
in bracket
37
[]
[]
For power
cord installations
only (see
the next step if using
conduit),
assemble
the strain
relief
in the hole. Insert
the
power
cord through
the strain
relief
and
tighten.
Allow
enough
slack to easily
attach
the cord terminals
to the terminal
block.
If tabs are present
at the end of
the winged
strain
relief,
they can be
removed
for better
fit.
NOTE: Do not install the power
cord
without
a strain relief. The strain relief
bracket
should be installed
before
reinstalling
the rear range wiring
cover.
Terminal
• /J
\
block
Strain relief
/
/
Power cord
Bracket
Skip to Step 4 or 5.
For conduit
installations
only, purchase
a
squeeze connector
matching
the diameter
of your conduit
and assemble
it in the hole.
Insert the conduit
through
the squeeze
connector
and tighten.
Allow enough
slack to
easily attach the wires to the terminal
block.
NOTE: Do not install the conduit
without
a
squeeze connector.
The squeeze connector
should
be installed
before
reinstalling
the
rear range wiring
cover.
Terminal
block
Squeeze
connector
Conduit
Skip to Step
6 or 7.
Bracket

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents