Installation Instructions
Electrical Connections
3
POWER CORD AND STRAIN
RELIEF INSTALLATION
A
Remove the wire cover
(on the back of the
range) by removing 2
screws, using a 1/4"
nut driver.
Do not discard these
screws.
B
Remove the knockout ring (1-3/8")
located on bracket directly below the
terminal block. To remove the knockout,
use a pair of pliers to bend the knockout
ring away from the bracket and twist
until ring is removed.
Knockout ring
in bracket
Wire
Cover
Terminal block
(appearance
may vary)
Knockout
ring removed
8
cont.
C
For power cord installations only (see
the next step if using conduit), assemble
the strain relief in the hole. Insert the
power cord through the strain relief and
tighten. Allow enough slack to easily
attach the cord terminals to the terminal
block. If tabs are present at the end of
the winged strain relief, they can be
removed for better fit.
NOTE: Do not install the power cord
without a strain relief. The strain relief
bracket should be installed before
reinstalling the rear range wiring
cover.
Strain relief
Power cord
D
For conduit installations only,
purchase a squeeze connector matching
the diameter of your conduit and
assemble it in the hole. Insert the conduit
through the squeeze connector and
tighten. Allow enough slack to easily
attach the wires to the terminal block.
NOTE: Do not install the conduit without
a squeeze connector. The squeeze
connector should be installed before
reinstalling the rear range wiring cover.
Squeeze
connector
Conduit
Terminal
block
Bracket
Terminal
block
Bracket