Electrical Connections
[_
emove house fuse or open circuit
breaker.
Loosen screws for the junction
box
cover and rotate out of place or remove
the cover.
Examine the junction
box location to
determine
the best routing of the
conduit, and select the best available
7/8" diameter
knockout.
Avoid using
holes in the top of the junction
box to
prevent the conduit from interfering
with the back of the range.
Break open the selected
knockout
by
placing a bladed screwdriver
on the
scored opening
in the junction
box and
striking the screwdriver
with a hammer.
(Pliers may be required to complete the
removal of the knockout.)
7/8" Knockout
Cover Rotated
From Box Opening
Position the range in front of the
opening,
but slightly to the side,
in a manner so that a person can enter
the opening to wire the range to the
house wiring in the junction
box.
Feed wires and conduit through the
open hole and snap the conduit fitting
into the hole. Route the conduit
in a
manner that will not interfere with the
rear wire cover. The conduit must be
routed below the wire cover.
WARNING:
Improper
connection
of aluminum
house
wiring to copper
leads can
result in an electrical
hazard or fire.
Use only connectors
designed
for
joining copper to aluminum
and follow
the manufacturer's
recommended
procedure
closely.
GENERAL
NOTE FOR ALL WIRE NUT
APPLICATIONS:
THE PROPER
SIZE WIRE
NUT SHALL BE PLACED
OVER THE
STRIPPED
LEADS AND THE WIRE NUT
TWISTED
UNTIL THE WIRE NUT CAN
NOT BE PULLED
FROM THE LEADS.
NO CONDUCTOR
SHALL BE EXPOSED
IN THE CONNECTION.
THE EXCEPTION
TO THE CONDUCTOR
BEING EXPOSED
IS THE BARE COPPER
GROUND
CONNECTION.
BREAKER
OR FUSE SIZE
240V
I
40 Amps
+
208V
I
40 Amps
+
+ NOTE: Check Local Codes for
required
breaker size.
6