Installation Instructions
I51Standard Installation Instructions
Installing the Anti-Tip Bracket
The anti-tip bracket is attached
to
the back of the Drop-In Range. It is
designed
to fit under the bottom of the
countertop
opening
at the rear. Measure
counter
thickness
at back of cutout to
determine
correct bracket location.
ANTI-TIP INSTALLATION
Select the proper position for the countertop
thickness
and move bracket to proper position.
(Unit is supplied with bracket in position
1 .)
(_
For 3/4" Counter
(_) For 1.18" (3 cm) Counter
(_
For 1.5" Counter
(_) For 3.5"
(_) Alternate
(shown below)
Glass Cooktop ----I
Anti-Tip Bracket Location
(Rear of Range)
Interior Wall -_
114" Min. Flat Area
Glass
Maintop
\
Bottom of
Countertop
to Engage
Bracket by
1/2" Min.
..,--Wall
Stud
Countertop
i
Thickness
Bottom of
- Countertop
Wire Cover
_
Y
ALTERNATE
ANTI-TIP INSTALLATION
Interior Wall_
Non-Kit ApI:
Glass Maintop \
_
_Wall
Stud
Countertop
Surface
10-3/8"
Non-Kit
Application
Anti-Ti I
*Attach ment
To Engage
Bracket By 1/2" Min.
_
ttachment
Anchored
To Wall Stud
Is Required
9
(Continued on following page)