installation
-&WARNING:
TEST FOR LEAKS
A complete
gos tightness check must be performed
at
the instollation
site.
Natural
Gas Leak
Test Points
-&CAUTION:
To prevent fire or explosion hozard, DO NOT use or
permit sources of ignition in the orea while performing
a leok test. Perform leak test outdoors only. Never
perform
o leok test with fire or flame. DO NOT SMOKE
WHILE PERFORMING THE LEAK TEST.
• Use on opproved
non-corrosive
leok detection
solution or creote o soopg solution of equal parts
mild dishwoshing
detergent
and woter.
Check to be sure all controls ore in the OFF position.
Turn on the fuel supplg. For naturol gos, turn manual
shut-off volve hondle 1/4 turn to olign with gos flow.
For LP,turn cglinder valve knob counterclockwise
one
full rototion.
ApplLI liquid leok detector
generouslLI on oll
connections
ond fittings. See illustrations.
• If growing
bubbles oppear on ong connection
point,
IMMEDIATELY turn off the gas supplg.
To stop a gas leak:
, Turn off the fuel supplg.
• Turn on control knobs to release pressure. Turn
controls OFF.
• Wash off soapLI solution ond towel drLI.
• Tighten the loose joint and perform a new leak test.
LP Gas Leak
Test Points
LP Gas Leak Test Points
With Cooktop
ToManifold..... _
7/
/%
//
3/8"
ToCooktop
\\
FromRegulatedf
II
LPTank
i,_