Natural Gas Grill Connections; To A Grill Or Cooktop - Monogram 31-10702 Installation Instructions Manual

Professional outdoor grills and cooktop
Table of Contents

Advertisement

Installation
Instructions
LP GAS GRILL CONNECTIONS
TO A GRILL OR COOKTOP {cont.}
Single
Gas Cooktop
or Grill Connection
LPHoseand
Regulator
3/8" Flare
Fitting
20-lb.Type1 LPTank
Built-in modelsshown.
Formodelsinstalledon carts, openthe tank storagedrawer on the
right sideto makethe tank connection.
Outdoor
Cooktop:
Install the cooktop with a
separate tank using the same method. Order
WB21X10156
Regulator hose assembly for the
20-lb. tank connection.
To connect
20-lb.
LP tank:
• Attach the regular hose assembly to the brass
elbow. Do not use threading
compound.
• Insert the coupler sleeve on the regulator
over
the tank inlet; turn clockwise to tighten.
Do not
overtighten
the coupler.
To disconnect
from
the 20-lb.
LP tank:
• Turn tank valve to OFF.
• Grasp the coupler sleeve, turn counterclockwise
and remove.
NATURAL GAS GRILL CONNECTIONS
• The gas supply line must be sized to
accommodate
the outdoor grill and, if present, an
outdoor
cooktop connected
to the same gas
supply.
• The grill or cooktop and its individual
shut-off
valve must be disconnected
from the gas supply
during any pressure testing of the system at test
pressures in excess of 1/2 PSIG.
1/2" Male to 3/4"
FemaleElbow
Regulator
_
3/4" NPTto
IncomingNatural
GasSupplyPipe
3/4" Min. Dia.
FlexibleConnector
ManualShut-Off
Valve
Built-in modelsshown.
Make connectionfor modelsinstalled on cartsin the same
manner. T heentry for the gas line is on the backof the cart.
Outdeer Ceektep: Installthe c00kt0pusingthe same method
illustratedabovefor the outdoorgrills.
The installation
of the outdoor
grills or cooktop
must
conform
with local codes or, in the absence of local
codes, with the National Fuel Gas Code, ANSI
Z22&:l, latest edition.
Operating
pressure is 4" water column. Supply
pressure should be 5" to 14" water column. If
pressure is more than 14" water column, a
step-down
regulator
is required.
Check with the local gas utility or with local codes
for instructions
on installing gas supply lines. Be
sure to check on type and size of run and how deep
to bury the line. If the gas line is too small, the grill
will not function
properly.
• Install a manual
gas shut-off valve in an easily
accessible location.
• Use threading
compound
on male threads only.
Do not use threading
compound
on the male end
of a flare adapter.
Make connections
as shown.
• Check to be sure the regulator
arrow points in the
direction
of gas flow, towards the grill and away
from the gas supply.