Installation Preparation
ELECTRICAL SUPPLY REQUIREMENTS
A 120-volt, 60Hz, 1S-amp power supplg is required.
An individual
properly grounded branch circuit or
circuit breaker is recommended.
Install a properly
grounded 3-prong electrical receptacle at the rear
and below the cutout. Electrical must be located
within reach of the 6-ft. power cord.
GROUNDING THE OUTDOOR COOKING
CENTER AND 2-BURNER COOKTOP
IMPORTANT: PLEASEREAD CAREFULLY.FOR
PERSONALSAFETY,THIS APPLIANCE MUST BE
PROPERLY GROUNDED.
The power cord of this appliance is equipped with a
3-prong (grounding) plug which mates with a standard
3-prong (grounding) wall receptacle to minimize the
possibilitg of electric shock hazard from this appliance.
Have the wall outlet and circuit checked by a qualified
electrician to make sure the outlet is properlg
grounded. Where a standard 2-prong wall outlet is
encountered, it is gout personal responsibilitg and
obligation to have it replaced with a properlg
grounded 3-prong wall outlet.
• DO NOT, UNDER ANY CIRCUMSTANCES,
CUT OR REMOVETHE THIRD (GROUND)
PRONG FROM THE POWER CORD.
DO NOT USEAN ADAPTERPLUG TO
CONNECTTHE OUTDOOR COOKING
CENTERTO A 2-PRONG OUTLET.
DO NOT USEAN EXTENSIONCORD
WITH THIS APPLIANCE.
• DO NOT PLACETHE UNIT IN STANDING
WATEROR ALLOW THE POWER CORD
TO BE IMMERSED.
THIS PRODUCT IS RECOMMENDED TO
BE CONNECTED TO A POWER
SOURCEWITH GROUND FAULT
CIRCUIT INTERRUPT(GFCI)
PROTECTION WHEN INSTALLED IN AN
OUTDOOR LOCATION. FOLLOW
LOCAL CODES.
If gou are uncertain about the GFCI protection on
the power source to which gou are connecting this
appliance, please contact a professional electrician
for verification.
GAS SUPPLY REQUIREMENTS
These grills are factorg-set
for either LP or natural
gas operation.
Do not attempt to operate the cooking center on a
different gas type than for what the grill orifices and
regulator are set. Check the rating plate to be sure
the gas supply matches the cooking product. Fuel
type conversion
requires a conversion
kit. Contact
your dealer or call 1.800.626.2002 to order.
GAS TYPE CONNECTIONS
AND CONVERSIONS
• WB28X10116
- LP to Natural Gas Operation
Conversion
Kit. This kit is for all grill models
and 2-burner cooktops.
Order this kit from
your Monogram
supplier.
WB28X10117
- Natural to LP Gas Operation
Conversion
Kit. This kit is for all grill models
and 2-burner cooktops.
Order this kit from
your Monogram
supplier.
• WB28X10118
- LP Portable/Stationarg
Conversion
Kit. To change the connection
from
LP portable
(20# tank) to whole house stationarg
tank or stationarg
tank to portable. Order this kit
from gour Monogram
supplier.
• WB28X10119
- High Altitude Conversion
Kit.
For operation
above 2,000 feet. Order this kit
from gour Monogram
supplier.
COOKTOP AND OUTDOOR COOKING
CENTER COMBINATION INSTALLATION
• Natural gas models are designed to operate
at 4" water column pressure. For proper
operation,
the pressure of the natural gas
supplied to the regulator
must be between
5" and 14" water column.
LP models are designed to operate
at 11" water
column pressure. For proper operation, the
pressure of the LP gas supplied to the regulator
must be between 12" and 14" water column.
Install a manual shut-off
valve in the gas line
(not provided), in an easilg accessible location.
Make sure the homeowner
knows where and
how to shut off the gas supplg to the grills.