Step 3: Provide Gas & Electrical Supply; Lp Gas Models; Natural Gas Models - Monogram ZGG48N42 Installation Instructions Manual

Stainless steel professional outdoor cooking centers
Table of Contents

Advertisement

3
S tep
Provide
Gas &
Electrical

LP GAS MODELS

Supply
• Connect the regulator/Quick Connect
• The Quick Connect type coupling requires
To connect the tank:
• Insert the coupler sleeve on the regulator over
To disconnect the tank:
• Turn off the main tank valve.
• Grasp the coupler sleeve and turn counter-

NATURAL GAS MODELS

The grill and its individual shut-off valve must
be disconnected from the gas supply during
any pressure testing of the system at test
pressures in excess of 1/2 PSIG.
The grill must be isolated from the gas supply
system by closing its individual shut-off valve
during any pressure testing of the system at
test pressures equal to or less than 1/2 PSIG.
The installation of these grills must conform
with local codes or, in the absence of local
codes, with the National fuel gas code, ANSI
Z223 latest edition.
Operating pressure is 4" W.C.
Supply pressure should be 5" to 14" W.C. If
pressure is more than 14" W.C. a step down
regulator is required.
Check with local gas utility or with local codes
for instructions on installing gas supply lines.
Be sure to check on type and size of run and
how deep to bury the line. If the gas line is too
small, the grill will not function properly.
WARNING
PRODUCT STORAGE
When storing LP models indoors, discon-
nect the LP tank. Store the tank outdoors
in a well ventilated area.
Do not store spare LP tanks in or near the
Outdoor Cooking Center enclosure.
assembly to the hose attached to the grill.
the user to pull on the outer sleeve of the
female coupling while simultaneously
inserting the male hose end into the coupling,
then release the locking outer sleeve.
the tank inlet, turn clockwise to tighten.
clockwise. Remove the inlet from the opening.
Installation
Outdoor Cooking Centers
Threading Compound Must Be
Resistant to L.P. Gas
L.P. Regulator Quick
Disconnect Hose
Assembly
LP operating pressure is 10" W.C.
CAUTION: The LP tank (shipped separately)
is a Type 1 Acme. Do not attempt to change
or alter these supplied parts Do not attempt
to use the regulator/hose assembly with a
standard 510 POL tank/valve assembly.
Coupler
1/2 NPT
Close Nipple
Adapter 1/2 NPT
to 3/8" Flare Fitting
Installer Supplied
Shut-Off
• Install a manual gas shut-off valve in an easily
accessible location.
• Use threading compound on male threads
only. Do not use threading compound on
the male end of the 1/2 NPT to 3/8 flare
adapter.
• Make connections as shown.
• Check to be sure the regulator arrow points
in the direction of gas flow, towards the grill
and away from the gas supply.
Coupler Sleeve
Main Valve
Inlet
L.P. Tank
Natural Gas 4.0" Regulator
Installer Supplied
TUBING (3/8" FLARE)
Natural Gas Supply