Fujitsu Mini-Split Manual page 34

Mini-split air conditioners and heat pumps
Table of Contents

Advertisement

MULTI ZONE MINI-SPLITS
Compact Duct
Built-in drain pump allows for
installation of compact duct unit
in smaller spaces than tradi-
tional units.
Traditional
Drain
13"
Pump
Compact Duct
9.4"
Return Air-intake Choices
Bottom
Standard Features
Wired Remote Control
Dry Mode
Weekly Timer
Auto Mode
Quiet Mode
Auto Restart/Reset
Condensate Pump
Fresh Air Intake
Flexible Installation
Horizontal or vertical*.
*Internal drain pump will not
operate when the unit is mounted
in a vertical configuration.
34
Nominal Cooling
Nominal Heating
Voltage/Frequency/Phase
Static Pressure
Air Circ.
C.F.M. (m
/h) Clg/Htg
3
Noise Level
dB(A) (Clg/Htg)
Running Current
(A)
Rated
Power Use
(W)
Rated
Fan Speeds Stage
Back
Connection Method
Conn. Pipe Diameter
Net Weight lbs.
Dimensions: Height
Width
Depth
Supply Duct Flange
Dimensions: Height
Width
Depth
Return Duct Flange
Dimensions: Height
Width
Depth
Field Supplied Filters
Filters are sized to keep
velocities and static
pressure loss low. This
will insure sufficient
static pressure is
available for ductwork,
fittings and supply
and return grilles. Alter-
native filter sizes with
equivalent face areas
can be used.
ARU9, 12RLF
ARU18RLF
ARU9RLF
ARU12RLF
Heat Pump
Heat Pump
9,000
BTU/h
10,200
BTU/h
208-230/60/1
208-230/60/1
0 ~ 0.36
0 ~ 0.36
In. W. C.
353 (600)
383 (650)
: Hi
324 (550)
353 (600)
Medium
294 (500)
324 (550)
Low
265 (450)
283 (480)
Quiet
28/28
: Hi
Medium
27/26
Low
26/25
Quiet
25/24
: Cooling
0.30
Heating
0.30
: Cooling
49
Heating
49
4 + Auto
4 + Auto
Air Filter
Washable
Washable
Flare
suc 3/8 dis 1/4
suc 3/8 dis 1/4
Inch
41 (19)
(kg)
7-25/32 (198)
7-25/32 (198)
Inch (mm)
27-9/16 (700)
27-9/16 (700)
Inch (mm)
24-13/32 (620)
24-13/32 (620)
Inch (mm)
5-15/16 (151)
5-15/16 (151)
Inch (mm)
Inch (mm)
25-19/32 (650)
25-19/32 (650)
Inch (mm)
3/4 (19)
6-27/32 (174)
6-27/32 (174)
Inch (mm)
22-19/32 (574)
22-19/32 (574)
Inch (mm)
3/4 (19) (Flat)
3/4 (19) (Flat)
Inch (mm)
R410A
Refrigerant
CFM
Typical Filter Size
Velocity, FPM
Unit External SP, in. W.C.
SP Loss, in. W.C.
Available Static Pressure
SP Loss, in. W.C.
Available Static Pressure
SP Loss, in. W.C.
Available Static Pressure
18, 24, 36,000 BTUs
ARU24RLF
ARU18RLF
ARU24RLF
Heat Pump
12,000
18,000
13,500
20,000
208-230/60/1
208-230/60/1
0 ~ 0.36
554 (940)
518 (880)
483 (820)
442 (750)
29/29
32/33
28/28
31/32
27/27
30/31
26/24
29/29
0.35
0.44
0.35
0.44
58
73
58
73
4 + Auto
Washable
Flare
Flare
suc 1/2 dis 1/4
suc 5/8 dis 1/4
41 (19)
50 (23)
7-25/32 (198)
7-25/32 (198)
35-7/16 (900)
43-5/16 (1,100)
24-13/32 (620)
24-13/32 (620)
5-15/16 (151)
5-15/16 (151)
33-15/32 (850) 41-11/32 (1,050)
3/4 (19)
3/4 (19)
6-27/32 (174)
6-27/32 (174)
30-15/32 (774)
38-11/32 (974)
3/4 (19) (Flat)
3/4 (19) (Flat)
R410A
R410A
ARU
ARU
ARU
9RLF
12RLF
18RLF
353
353
547
12 x 20
12 x 20
14 x 25
212
212
225
0.36
0.36
0.36
1" Fiberglass Filter
0.04
0.04
0.04
0.32
0.32
0.32
1" MERV 8 Pleated Filter
0.12
0.12
0.14
0.24
0.24
0.22
2" MERV 8 Pleated Filter
0.07
0.07
0.08
0.29
0.29
0.28
48,000 BTUs
Heat Pump
24,000
27,000
0 ~ 0.20
783 (1,330)
730 (1,240)
648 (1,100)
607 (1,030)
33/35
32/34
30/32
29/29
0.66
0.66
111
111
4 + Auto
Washable
Flare
59 (27)
3/4 (19)
R410A
ARU
24RLF
806
18 x 30
215
0.20
0.04
0.16
0.13
0.07
0.07
0.13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents