Fujitsu Mini-Split Manual page 24

Mini-split air conditioners and heat pumps
Table of Contents

Advertisement

SINGLE ZONE MINI-SPLITS
High Performance Heating
Heating capacity at low
outdoor temperatures is
achieved by adopting a
large heat exchanger
and a high capacity
7
compressor. Systems
operate down to -5°F.
6
Standard Features
Wired Remote Control
W
ired
Weekly Timer
7
7
Dry Mode
6
D
ry
6
6
Auto Mode
POWERFUL
Economy Mode
50 F
Minimum Heat
POWERFUL
Auto Restart/Reset
*Available only with optional wireless remote controller.
^Operation monitoring and On/Off control only.
POWERFUL
Field Supplied Filters Used With Compact Duct Units
Although Compact Duct units come with factory filters, when return
ductwork is used field supplied filters are more practical to use. They
can be installed at the unit or for more convenient servicing, in filter
grilles. See the guidelines to the right to determine filter sizes.
POWERFUL
The chart includes CFM, external static pressure capability and a
typical filter size for each model. Filters are sized to keep velocities
and static pressure loss low. This will insure sufficient static pressure
is available for ductwork, fittings and supply and return grilles.
24
Federal Tax Credit Qualified
$
See Page 9 for details
Systems 9RLFCD and 12RLFCD only.
75°F
When
used
Single
on
Zone
other
models
+5°F
-5°F
7
7
6
7
Auto Changeover
6
L
ow
Low Ambient Cooling
A
mbient
7
Cold Prevention
C
old
Daisy Chain
16
D
aisy
Built-In Condensate Pump
P
ump
I/O
*
Auto
3rd Party Device Control
POWERFUL
3
rd
P
arty
7
6
Alternative filter sizes with equivalent face
areas can be used. After deducting filter
loss, available
static pressure values are shown.
A fiberglass filter is shown in blue
to the left. A MERV pleated filter is
shown in white.
Up to 21.5 SEER
Multi-Tenant
Dwellings
Optional Accessories
Backlit Wired Remote Control
UTY-RVNUM Displays room temp.
Wireless Remote and Receiver
Unit UTY-LRHUM
^
Typical Filter Size
Velocity, FPM
Unit External SP, in. W.C.
SP Loss, in. W.C.
Available Static Pressure
SP Loss, in. W.C.
Available Static Pressure
SP Loss, in. W.C.
Available Static Pressure
Hotels / Motels
Dorms
UTY-RVNUM
ARU
ARU
ARU
9RLF
12RLF
18RLF
CFM
353
353
12 x 20
12 x 20
14 x 25
212
212
0.36
0.36
1" Fiberglass Filter
0.04
0.04
0.32
0.32
1" MERV 8 Pleated Filter
0.12
0.12
0.24
0.24
2" MERV 8 Pleated Filter
0.07
0.07
0.29
0.29
547
225
0.36
0.04
0.32
0.14
0.22
0.08
0.28

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Mini-Split and is the answer not in the manual?

Questions and answers

David Pendlebury
February 5, 2025

I have three Fujitsu HVAC systems installed in my condominium (P/N 9373329206). I would like to replace the existing Wired Controllers with your Kagami Wired Remote Controller system(UTY-RVRU?). Are the new controllers retrofittable to my system and, if so, how can I get an installed cost estimate? Thanks, David

User image 67a3873aa6efa
benjamin rush
March 25, 2025

How do you use your Remote

1 comments:
Mr. Anderson
March 25, 2025

To use the remote for a Fujitsu Mini-Split:

1. Slide Down the Door – At the bottom of the remote, there are programming functions.
2. Programming – Follow the manual step by step to set a weekly program or sleep timer. Avoid using it if unsure, as incorrect settings may cause issues.
3. Reset Button – If a mistake is made during programming, use the reset button to restore factory settings.
4. Mode Selection – For heating season, set the mode to "Heat" using the mode button.

For wired remote controllers, installation involves:
- Stripping the remote controller cable.
- Removing the front and rear case using a flat-blade screwdriver.
- Mounting the rear case on a wall or box with screws.
- Connecting the required cables.

Additional features may include integration with automation systems, occupancy sensors, and other heating/cooling devices.