Kenmore HE4 110.8508 Series Use And Care Manual page 9

Electric dryer
Hide thumbs Also See for HE4 110.8508 Series:
Table of Contents

Advertisement

Available languages

Available languages

Power Supply Cord
Direct Wire
Fire Hazard
Use a new UL listed 30 amp power supply cord,
Use a UL listed strain
reliefo
Disconnect
power before making electrical
connections,
Connect neutral wire (white or center wire) to center
terminal
(silver)°
Ground wire (green or bare wire) must be connected
to
green ground connecter°
Connect remaining
2 supply wires to remaining
2 terminals
(gold).
Securely tighten
all electrical
connections,
Failure to do so can result in death, fire, or
electrical
shock.
1. Disconnect
power,
2. Remove the hold-down
screw and terminal block cover.
J
D
/
A. Neutral grounding
wire (green with yellow stripes)
B. External ground conductor screw
C. Center, silver-colored
terminal block screw
D. Terminal block cover and hold-down
screw
Fire Hazard
Use 10 gauge solid copper wire,
Use a UL listed strain relief,
Disconnect
power before making electrical
connections,
Connect
neutrat wire (white or center wire) to center
terminal
(silver).
Ground wire (green or bare wire) must be connected
to
green ground connector,
Connect
remaining
2 supply wires to remaining
2 terminals
(gold),
Securety
tighten
all electrical
connections,
Failure to de so can result in death, fire, or
electrical
shock,
3. Add strain relief.
Style 1: Power supply cord strain relief
Remove the screws from a 3/4"(1.9 cm) UL listed strain
relief (UL marking on strain relief). Put the tabs of the two
clamp sections into the hole below the terminal block
opening so that one tab is pointing up and the other is
pointing down, and hold in place. Assemble and tighten
strain relief screws just enough to hold the two clamp
sections together.
.........
B
A. Strain relief tab
B. Clamp section
Put power supply cord through the strain relief. Be sure
that the black part of the power supply cord is inside the
strain relief. The strain relief should have a tight fit with the
dryer cabinet and be in a horizontal position.