Kenmore HE4 110.8508 Series Use And Care Manual page 12

Electric dryer
Hide thumbs Also See for HE4 110.8508 Series:
Table of Contents

Advertisement

Available languages

Available languages

3,
Connect ground wire (green or bare) of power supply cable to
external ground conductor screw. Tighten screw.
C
2,
Connect neutral wire (white or center wire) of power supply
cord to the center, silver-colored
terminal screw of the
terminal block. Tighten screw.
D
D
E
A. External ground conductor screw
B. Green or bare copper wire of power supply cable
C. _" (1.9 cm) UL ilsted strain relief
D. Center silver-colored
terminal block screw
E. Neutral grounding
wire (green with yellow stripes)
E Neutral wire (white or center wire)
4. Place the hooked end of the neutral wire (white wire) of power
supply cable under the center screw of terminal block (hook
facing right). Squeeze hooked end together. Tighten screw.
5. Place the hooked ends of the other power supply cable wires
under the outer terminal block screws (hooks facing right).
Squeeze hooked ends together. Tighten screws.
!! !!
6. Tighten strain relief screw.
7.
Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
3-wire connection:
Power supply cord
Use where local codes permit connecting cabinet-ground
conductor to neutral wire.
B
D
E
C
A. 3-wire receptacle
(NEMA type 10-30R)
B. 3-wire plug
C. Neutral prong
D. Spade terminals with up turned ends
E. _" (1.9 cm) UL listed strain relief
E Ring terminals
G. Neutral (white or center wire)
1. Loosen or remove center terminal block screw.
G
F
A. Externalground conductor screw
B.Neutral grounding wire (green with yellow stripes)
C. Center silver-colored terminal block screw
D. Neutral wire (white or center wire)
E. _" (1.9 cm) UL Iisted strain relief
3. Connect the other wires to outer terminal block screws.
Tighten screws.
4. Tighten strain relief screws.
5. Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
3-wire connection:
Direct wire
Use where local codes permit connecting cabinet-ground
conductor to neutral wire.
Direct wire cable must have 5 ft (1.52 m) of extra length so dryer
can be moved if needed.
Strip 31/2 '' (8.9 cm) of outer covering from end of cable. Strip
insulation back 1" (2.5 cm). If using 3-wire cable with ground
wire, cut bare wire even with outer covering. Shape ends of wires
into a hook shape.
4'
When connecting to the terminal block, place the hooked end of
the wire under the screw of the terminal block (hook facing right),
squeeze hooked end together and tighten screw. See example
below.
1. Loosen or remove center terminal block screw.
12

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

110.8586110.8587He4 110.8586 seriesHe4 110.8587 series

Table of Contents