Indoor Unit Installation
1.
Installing the mounting plate
• The mounting plate should be installed on a wall which can support the weight of the indoor unit.
1) Temporarily secure the mounting plate to the wall, make sure that the plate is completely level, and mark the boring
points on the wall.
2) Secure the mounting plate to the wall with screws.
Recommended mounting plate retention spots and dimensions
Recommended mounting plate
retention spots (5 spots in all)
(Bolt size: 3/8 (M10))
4-47/64
(120.5)
2-9/64
6-19/64
(54.5)
(160)
* The removed pipe port cover can be
kept in the mounting plate pocket.
■English
Place a leveler
on raised tab.
7-63/64
(203)
Gas pipe end
1-31/32
Liquid pipe end
(50)
13-1/64
(330.5)
30-5/16
(770)
Removed pipe
port cover
Use tape measure as shown.
Position the end of a tape
.
measure at
(Bolt size: 3/8 (M10))
4-31/32
9-23/32
(101)
(247)
6-19/64
(160)
13-1/32
(331)
A
Mounting plate
2-1/8
Through-
the-wall hole
(54)
φ2-9/16 (φ65)
Drain hose
unit: inch (mm)
position
5