Indoor Unit; Installing The Mounting Plate; Drilling A Wall Hole And Installing Wall Embedded Pipe - Daikin GTKC48UV16W Operation Manual

Hide thumbs Also See for GTKC48UV16W:
Table of Contents

Advertisement

Installing The Mounting Plate

• The mounting plate should be installed on a wall which can support the weight of the indoor unit.
1) Temporarily secure the mounting plate to the wall, make sure that the panel is completely level, and mark the
boring points on the wall.
2) Secure the mounting plate to the wall with screws.
Recommended mounting-plate retention spots and Dimensions
t
Recommended mounting plate
retention spots fl spots in all)
t Recommend e d mounUng p l a t e
ret e nt i onspot s (7spots1nal l )

Drilling A Wall Hole And Installing Wall Embedded Pipe

L'.t
WARNING----------------
For metal frame or metal board walls, be sure to use a wall embedded pipe and wall hole cover in the feed-through hole
to prevent possible heat, electrical shock, or fire.
1) Drill a feed-through hole with a 65mm
diameter through the wall at a
downward angle toward the outside.
2) Insert a wall embedded pipe into the hole.
3) Insert a wall hole cover into wall pipe.
5

Indoor Unit

Use a tape measure
as shown.
Place a leveler
Position the end of
on these tabs.
the tape measure at I>
Gas pipeend
Drainhose
Liquid pipe and
position
Wall embedded
pipe (field supply)
Wall hole cover
(field supply)
Applicable Unit Size*
[H] X [W] X [D]
Type
CD
298
800
X
0
298
821
X
®
298
885
X
©
298
906
X
* Unit size available on name plate.
Applicable Unit Size*
Type
®I
* Unit size available on name plate.
Inside......., Outside
A
B
C
229
800 116.5 116.5
X
235
821
126.5
128
X
229
885 116.5 116.5
X
235
906
127
127.5
X
Table No.4
I
[H] X [W] X [D]
310
1100
239
X
X
Table No. 5
All dimensions are in mm.