Preparation Before Operation

I I I I
Tips for saving energy
Be careful not to cool (heat) the room too much.
Keeping the temperature setting at a moderate level helps save energy.
Cover windows with a blind or a curtain.
Blocking sunlight and air from outdoors increases the cooling (heating) effect.
I I I I
Operation range
If the temperature or the humidity is beyond the following conditions, safety devices may work and the air conditioner
may not operate, or sometimes, water may drop from the indoor unit.
Cooling
INDOOR
TEMPERATURE
80% or below
DB
70 to 90 °F
(Long time operation in a humid-
ity over 80% may cause conden-
WB
57 to 77 °F
sation on the unit and dripping.)
DB: Dry bulb temperature WB: Wet bulb temperature
The setting temperature range of the remote controller is 60°F to 90°F.

Useful Information

Observe the following precautions to ensure the system operates properly.
• Set the room temperature appropriately.
Take care not to cool or heat the room excessively.
Adjust the temperature so that everyone in the room is comfortable.
• Ventilate the room from time to time.
Be sure to ventilate the room after using the air conditioner for a long time.
• Do not leave the door or window open.
The air will be released, and the effect of cooling/heating
will be reduced.
• Do not allow direct sunshine to enter the room during the cooling
operation.
Hang a curtain or blind to the window to prevent direct sunshine.
• Keep televisions, radios or stereo equipment at least 3.5ft. from
the indoor unit or remote controller.
Otherwise, picture
disturbance or
noise may result.
6
OUTDOOR TEM-
HUMIDITY
DB
Heating
INDOOR TEMPERA-
PERATURE
DB
23 to 115 °F
**–4~5°FWB: Range for operation
5~60°FWB: Range for continuous operation
• Turn off the power when the air conditioner is not used
for a long time.
With the power on, the air conditioner will consume several
to several tends of watts of power (∗1)
NOTE
∗1 The power consumption while the equipment is stopped var-
ies with the type of outdoor unit, etc. Consult your dealer for
further details on power consumption.
• Do not use and room heater under the indoor unit.
Heat may deform the suction grille of indoor unit.
• Do not place things near the air outlet or air inlet.
Such obstacles may lower the performance of the air condi-
tioner or make it stop.
• When the display shows "
FILTER), refer to the instruction manual of the indoor
unit, and clean the air filter.
Recommended temperature setting
For cooling
79 to 83 °F
For heating
68 to 75 °F
OUTDOOR
TURE
TEMPERATURE
DB
–4 to 70 °F**
59 to 81 °F
WB
–4 to 60 °F**
OFF
" (TIME TO CLEAN AIR