ice Maker
Dran
Pump
InstaJJat
on (on
some models)
NOTE: Connect drain pump to your drain in accordance with all
Drain Cap
state and local codes and ordinances.
It may be desirable to
insulate drain tube thoroughly
up to drain inlet to minimize
condensation
on the drain tube. Insulated tube kit Part Number
W10365792 is available for purchase. Drain pump is designed to
pump water to a maximum height of 10 ft (3 m). Use only
Whirlpool approved drain pump kit Part Number 1901A.
Kit Contains:
Drain pump kit Part Number 1901A
8/8"ID x 51/8'' drain tube (ice maker bin to drain pump reservoir
inlet)
1/2"ID x 10 ft (3 m) drain tube hose (drain pump discharge to
household drain)
8/le" ID x 32" (81 cm) vent tube (drain pump reservoir vent to
ice maker cabinet back)
Cable clamps (secures vent tube to back of ice maker) (3)
#8-32 x 3/8"pump mounting screws (secures drain pump to
baseplate and clamps to back of ice maker) (5)
8/8"small adjustable hose clamp (secures vent to drain pump)
7/8"large adjustable hose clamp, (secures drain tube to ice
maker bin and drain pump reservoir inlet) (3)
Rear panel (2)
Instruction sheet
O
If Ice Maker Is Currently
Installed
NOTE: If ice maker is not installed, please proceed to "Drain
Pump Installation" section.
1. Push the selector switch to the Off position.
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical
shock.
2. Unplug ice maker or disconnect
power.
3. Turn off water supply. Wait 5 to 10 minutes for the ice to fall
into the storage bin. Remove all ice from bin.
4. Unscrew the drain cap from the bottom of the water pan
located inside the storage bin. Allow water to drain
completely.
Replace drain cap. See "Drain Cap" illustration.
A. Drain cap
5. If ice maker is built into cabinets, pull ice maker out of the
opening.
6. Disconnect
water supply line. See "Water Supply Line"
illustration.
Water Supply
Line
A. _" copper tubing
B. Cable clamp
C. _" compression
nut
E
D. Ferrule (sleeve)
E. Ice maker connection
Drain Pump Installation
NOTE: Do not kink, smash or damage tubes or wires during
installation.
1. Unplug ice maker or disconnect
power.
2. Remove rear panel. See "Rear Panel" illustration for 5 screw
locations. Pull rear panel away from the drain tube and
discard.
Rear Panel
A
A. Screw locations
10