Programming
GENERAL
Tank Temp.
"OFF" allows
Brew at Temp.
brewing at any
temperature.
• Temperature
Units of Meas.
• Volume
Logo Timeout
Brew B. Sensor
Programming
INPUTS
• Input
Display Inputs
Summery
Cal. Touch Scr
Chart to correct for boiling point for altitude
in tank water temperature.
Suggested
Altitude (ft.)
Setting(°F)
0
200
500
200
1000
200
2000
200
2500
200
3000
200
3500
197
4000
195
4500
194
5000
194
5500
193
6000
192
6500
191
7000
190
7500
188
8000
187
Factory set
Items
Default
200°F
AUTO
°F
Liters
1:00 mm:ss
NORMAL
Factory set
Items
Default
Calibrate
BREW AT TEMP: AUTO
Boiling
(DEFAULT: FACTORY PROGRAMMED INTO BREWER)
point (° F)
This allows the "BREW START" to active. If the hot water
212.0
tank is at the selected temperature—the brew will start.
211.1
If the temperature is too low, the brewer will wait until the
210.2
proper temperature is reached. A screen (example to the
208.4
right) will display showing a thermometer icon and the tank
temperature.
207.5
IMPORTANT: ALWAYS have dispenser(s) under the brew
206.6
baskets when in the BREW AT TEMP mode.
205.7
BREW AT TEMP: ON
204.8
"BREW START" Batch Section Buttons will not be
203.9
accessible until tank temperature is at set point.
203.0
The "BREW START" screens with the Batch Section
Buttons become accessible when hot water tank is at the
202.0
selected temperature. The screen at right displays when
201.1
the "BREW AT TEMP" is selected.
200.2
199.3
BREW AT TEMP: OFF
198.3
Allows brewing at any temperature above 179°F/82°C. (Not recommended)
197.4
.
Programming Range
(display)
200 °F
|______________[]___|
180
AUTO
|____________[]___|
OFF
ON AUTO
°F
|___[]____________|
°F
°C
Liters
|_____________[]__|
Gallons
Liters
1:00 mm:ss
|_[]_______________|
0:00
NORMAL
|__[]____________|
NORMAL
OVERRIDE
Programming Range
(display)
Brew Basket Sensor
High Liquid Level probe
High Tank Temperature Probe
Lower Tank Temperature Probe
SD Card Recognized
USB Drive Recognized
Calibrate
________________[]____
YES
BREW AT TEMPERATURE DEFINITONS
USER SELECTABLE
USER SELECTABLE
14
Notes
Correction for high
altitude below
207
SEE NOTE BELOW!
5:00
Notes
USB is for factory
setup only
If Yes:
Follow directions on
NO
the touch screen