Unit Wiring Diagrams - KitchenAid KULSL85 Installation Instructions Manual

Automatic ice maker
Table of Contents

Advertisement

21
nit Wiring Diagrams
This model operates at 115 volts except for
the cutter grid circuit which operates at 8.5
volts at 1 amp.
The compressor
runs at all times except
when the Bin Thermostat
becomes satisfied
and opens the circuit. This de-energizes
the
system except for the transformer and cutter
grid.
Under normal operating conditions, when
the evaporator reaches the preset tempera-
ture (+lO" to -3°F [-12" to -1 9"C], depending
on thickness of ice) the evaporator thermo-
stat opens, terminating
operation of the fan
motor and pump motor. The hot gas sole-
noid and the water valve solenoid are
energized at this time and remain so until the
evaporator reaches 38" + 2°F (3" + 1%).
Electrical Shock Hazard
Disconnect power before servicing unit.
Failure to do so could result in electrical
shock.
NOTE:
Maximum fuse size: 15 amps.
Check
Operation
a0
Start the unit by turning the service
switch to "ON" and opening the line
water valve.
tH
NOTE:
Left is "OFF' - Middle is "ON" -
Right is "CLEAN." In 'CLEAN" position,
only the pump operates.
d
Check condenser fan to make sure it is
revolving. Check for airflow. Do not
insert hand into fan area.
d
Water will not enter pump pan until
freezing plate gets cold and machine
goes into a harvest cycle.
d
Check for even water flow over freez-
ing plate. Unit must be level for proper
operation.
d
Check for desired cube thickness and
after 24 hours adjust if necessary.
Maximum ice yield will be obtained
with ice thickness at l/i' (13 mm) to %"
(16 mm).
d
Replace grille.
11