Grounding Instructions - Windsor MPRO Operator Instructions Manual

Mini carpet extractor 4 gallon
Hide thumbs Also See for MPRO:
Table of Contents

Advertisement

THIS PRODUCT IS FOR COMMERCIAL
USE ONLY.
ELECTRICAL
In the USA this machine operates on a standard 15
amp 120V, 60 hz, A.C. power circuit. The amp, hertz,
and voltage are listed on the data label found on each
machine. Using voltages above or below those
indicated on the data label will cause serious damage
to the motors.
EXTENSION CORDS
If an extension cord is used, the wire size must be at
least one size larger than the power cord on the
machine, and must be limited to 50 feet (15.5m) in
length.

GROUNDING INSTRUCTIONS

This appliance must be grounded. If it should malfunc-
tion or break down, grounding provides a path of least
resistance for electric current to reduce the risk of
electric shock. This appliance is equipped with a cord
having an equipment-grounding conductor and
grounding plug. The plug must be inserted into an
appropriate outlet that is properly installed and
grounded in accordance with all local codes and ordi-
nances.
GROUNDED
OUTLET
GROUNDING
PIN
GROUNDED
OUTLET BOX
METAL SCREW
(A)
86037780 MINI EXTRACTOR
120 VOLT MODELS
This appliance is for use on a nominal 120-volt circuit,
and has a grounded plug that looks like the plug in "Fig.
A". A temporary adaptor that looks like the adaptor in
"Fig. C" may be used to connect this plug to a 2-pole
receptacle as shown in "Fig. B", if a properly grounded
outlet is not available. The temporary adaptor should
be used only until a properly grounded outlet (Fig. A)
can be installed by a qualified electrician. The green
colored rigid ear, lug, or wire extending from the
adaptor must be connected to a permanent ground
such as a properly grounded outlet box cover.
Whenever the adaptor is used, it must be held in place
by a metal screw.
Improper connection of the equipment-grounding
conductor can result in a risk of electric shock. Check
with a qualified electrician or service person if you are
in doubt as to whether the outlet is properly grounded.
Do not modify the plug provided with the appliance - if it
will not fit the outlet, have a proper outlet installed by a
qualified electrician.
Le raccordement incorrect du conducteur de terre
d'équipement peut entraîner des risques d'électrocu-
tion. Vérifiez auprès d'un électricien qualifié ou d'un
responsable de l'entretien si vous avez quelque doute
que ce soit quant au raccordement à la terre de votre
prise murale. Ne modifiez pas la fiche fournie avec
l'appareil : si elle ne correspond pas à la prise murale,
faites installer une prise adéquate par un électricien
qualifié.
(B)
Safety
ADAPTER
TAB FOR
GROUNDING SCREW
(C)
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

MprogbMproauMproeu100803901008040010080410 ... Show all

Table of Contents