Using a USB Hub
The unit has a USB hub. Connect the supplied USB
cable between the unit and the computer. You can also
connect multiple units in a chain, or connect the
calibration sensor to the unit directly.
Notes
• This USB hub is only for use with an LMD-DM series
LCD Display and the optional calibration sensor.
• Proper operation of all USB devices connected to the
USB hub is not guaranteed.
1
Connect the supplied DVI cable between the unit
and computer, and turn on the computer (page 15).
2
Connect the supplied USB cable between the unit's
UP (USB upstream) port and the computer's (or
another USB hub's) USB down (USB downstream)
port.
The USB function is automatically set up.
Rear of the unit
Connecting the supplied USB cable also enables the
following:
• To calibrate the unit (An optional calibration kit is
required.)
• To calibrate multiple units in a chain
To calibrate the unit
Connect the supplied USB cable between the unit's
UP (USB upstream) port and the computer's USB down
(USB downstream) port.
For more information, refer to the instruction manual for
the calibration kit.
To calibrate multiple units in a chain
Up to six units can be connected using the USB cables.
1
Connect the supplied USB cable between the 1st
unit's
computer's USB down (USB downstream) port.
2
Connect the supplied USB cable between the 1st
unit's
2nd unit's
3
Repeat step 2 to connect the 3rd, 4th, and 5th unit
in the same way.
4
Connect the supplied USB cable between the 6th
unit's
computer's USB down (USB downstream) port.
Computer
6th
Note
Up to five units can be connected in a daisy chain.
UP (USB upstream) port and the
DOWN (USB downstream) port and the
UP (USB upstream) port.
UP (USB upstream) port and the
3rd
2nd
5th
4th
Computer
1st unit
23
Using a USB Hub