Gs1 Databar Expanded Message Length; Gs1 Emulation - Honeywell 2020-5 User Manual

Cordless system
Table of Contents

Advertisement

GS1 DataBar Expanded
* On
Off

GS1 DataBar Expanded Message Length

Scan the bar codes below to change the message length. Refer to
Message
Length
on page 6-2 for additional information. Minimum and Maximum
lengths = 4-74. Minimum Default = 4, Maximum Default = 74.
Minimum Message Length
Maximum Message Length

GS1 Emulation

The imager can automatically format the output from any GS1 data carrier to
emulate what would be encoded in an equivalent GS1-128 or GS1 DataBar
symbol. GS1 data carriers include UPC-A and UPC-E, EAN-13 and EAN-8,
ITF-14, GS1-128, and GS1-128 DataBar and GS1Composites. If GS1-128
Emulation is selected, the AIM Symbology Identifier will be reported as "]C1". If
GS1 DataBar Emulation is selected, the AIM Symbology Identifier will be
reported as "]e0." Any application that accepts GS1 data can be simplified
since it only needs to recognize one data carrier type. Default = GS1 Emulation
Off .
GS1 DataBar Emulation
128 Emulation
* GS1 Emulation Off
6 - 30

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

2020-5b202038203820i

Table of Contents