Feature #7 Extended Starter Cranking Time
Default Setting Min (.75 Second) (
Options:
press "disarm/unlock" button to program
Medium Lo (1.00 Second) (
press "II" button to program
Medium Hi (1.5 Second)
(
Maximum (2.25 Second)
(
press "III" button to program
Extended Starter Cranking Time operates in conjunction with the previous feature's
"Tachless" setting. This feature sets the starter output's crank time. The four
different settings indicate the crank time for the first crank attempt. The system will
make up to 4 starting attempts and each additional attempt will increase the crank
time by 0.2 second. This feature should only be programmed by the installer.
Feature #8 Programmable Remote Start Relay
Default Setting
Ignition Output (
Options:
press "disarm/unlock" button to program
Accessory Output
(
press "II" button to program
Starter Output
(
The system features 4 dedicated remote start output relays, one of which is
programmable (this is the unit's large blue output wire). Operation choices are
ignition, accessory or starter power output.
programmed by the installer.
Feature #9 Arm, Disarm or Additional Channels
Default Setting
Arm / Disarm (
Options:
Arm / Channel 5
(
press "disarm/unlock" button to program
press "II" button to program
Channel 4 / Disarm
(
press "III" button to program
Channel 4 / Channel 5
(
The system has outputs designed for arming and/or disarming a factory-equipped
security system. These wires may be used instead to provide further system outputs,
which are remotely operated by the transmitter. These outputs are in addition to
the 2nd channel and 3rd channel outputs, the operation of all of these outputs is
explained on page 17.
As shown in the programming assignment, the arm, disarm, channel 4 and
channel 5 are programmable as various combinations. For example, if the disarm
output is needed, but not the arm output, then channel 4 may be made available for
use.
Feature #10 Gasoline Or Diesel Engine
Default Setting
Gasoline
Option:
Diesel
(
press "disarm/unlock" button to program
This feature changes the system's timing of the ignition and starter output sequence
for remotely starting vehicles with a diesel engine. This feature should only be
programmed by the installer.
press "arm/lock" button to program
)
)
press "arm/lock" button to program
)
This feature should only be
press "arm/lock" button to program
)
)
press "arm/lock" button to program
(
Page - 38
)
)
Status Light, Valet Switch, Transmitter
Using the System ..................................................................... 7
Arming Bypass, Sensor Bypass
Prewarning
)
)
Safety Features, Stick Shift Remote Starting; Pit-Stop; Turbo Timer
Low Voltage and Low Temperature Starting, 2nd Channel, 3rd Channel, Silent
)
Arming & Disarming
)
SecureCode .............................................................................. 19-20
The Status Light ...................................................................... 20-21
Transmitter Protection ............................................................. 22
How to program Transmitters....................................................... 23
How to Program Features ........................................................ 24-25
User Programmable Features ................................................... 26-33
Installer Programmable Features ............................................. 34-38
Complete Programmable Features Matrix ................................ 39
)
Limited Lifetime Warranty .............................................. Back Cover
)
This Booklet Contains
,
Sensor Bypass