System Armed And Activated - Crime Guard 328i4 Operation Manual

Table of Contents

Advertisement

Feature #16 Remote Activated Vehicle Recovery
This form of Vehicle Recovery is initiated by a signal from the transmitter. The
Vehicle Recovery operation, and the three ways to initiate it are described on page
17. When programming this feature, press the transmitter's Upper Left "Lock"
Button to turn it on, or press the Upper Right "Unlock" Button to turn it off.
Feature #17 Chirp Confirmation
This feature removes the system's 1 arming and 2 disarming confirmation chirps.
When this feature is used to remove these chirps, the system will still have 4 chirps
upon arming if a protected zone is violated, and still have 3 chirps upon disarming
if the system was previously activated. Using this feature to turn off the arm and
disarming chirps will also not affect the Prewarning operation, Unauthorized
Transmitter Alert, nor will it affect the chirps used in transmitter or features
programming.
When programming this feature, press the transmitter's Upper Left "Lock"
Button to turn on the arm and disarming chirps, or press the Upper Right "Unlock"
Button to turn them off.
Feature #18 Steady Siren or Pulsed Horn Output
It is possible to utilize the vehicle's existing horn for the audible part of the system's
operation. This feature changes the audible output of the system from the steady
output required by the electronic siren to a pulsed output which is suitable for oper-
ating the horn. When programming this feature, press the transmitter's Upper Left
"Lock" Button to configure the output as pulsed; or press the Upper Right "Unlock"
Button to set the steady siren output.
Feature #19 Confirmation Chirp Volume
This feature allows the choice of four different volume levels of the system's con-
firmation chirps.
Upper Left "Lock" Button =
lowest chirp volume (8mS);
system responds with 1 chirp
Lower Left " : " Button =
medium high chirp
volume (30mS); system
responds with 3 chirps
Page 26
(Factory Default Setting Off)
(Factory Default Setting On)
(Factory Default Setting Steady Siren)
(Factory Default
Setting Medium High)
Upper Right "Unlock" Button =
medium low chirp volume (12mS);
system responds with 2 chirps
: :
Lower Right " " Button=
highest chirp volume (50mS);
system responds with
4 chirps
again at the beginning.
• Last Door Arming is separate from, and does not effect the operation of
arming by using the transmitter.
• All protected points must be closed or otherwise in a non-violated state
for the Last Door Arming sequence to start. Unlike active arming from
the transmitter, the system can not bypass an open or detected zone and
arm itself.
To temporarily prevent the system from arming itself:
• Place the system into Valet Mode using the Valet Switch.
• Leave a vehicle door open. Although this varies depending on the vehicle,
in some cases turning on the interior light will be detected by the system
as an open door.
• Although the system will not Last Door Arm while the ignition is on,
leaving the ignition key turned on without the engine running is not
recommended.
SYSTEM ARMED & ACTIVATED
While the system is in the Armed state:
The Status Light will be flashing slowly to confirm that the system is
armed, and also serve as a visual deterrent.
Protected zones are being monitored for intrusion attempts.
If an optional starter interrupt is installed, it will engage.
Should an activation into the alarm condition occur:
The polyrythmic changing-tone electronic psycho siren will loudly sound.
The parking lights will flash.
The doors will lock, regardless of their locked or unlocked status. This
feature is unique- if the system detects that a door is opened, it waits until
the door is closed before relocking it, denying the thief reentry.
An activated alarm condition has a duration of 30 seconds (60 is optional)
unless the system is disarmed using the transmitter or by Emergency
Override using the Valet Switch. If all protected zones are secure at the end
of the alarm condition, the system will stop and rearm automatically, ready
to detect another entry attempt. If a protected zone is still violated at the end
of the alarm condition, the system will reactivate for up to two additional
Page 7