Installation Instructions - GE GeoSpring GEH50DEED Owner's Manual

Hybrid electric residential water heaters
Hide thumbs Also See for GeoSpring GEH50DEED:
Table of Contents

Advertisement

Available languages

Available languages

Installation instructions
The manufacturer's warranty does not cover any
damage or defect caused by installation, attachment
or use of any type of energy-saving or other
unapproved devices (other than those authorized by the
manufacturer) into, onto or in conjunction with the water
heater. The use of unauthorized energy-saving devices
may shorten the life of the water heater and may
endanger life and property.
The manufacturer disclaims any responsibility for
such loss or injury resulting from the use of such
unauthorized devices.
If local codes require external application of insulation
blanket kits, the manufacturer's instructions included
with the kit must be carefully followed.
Application of any external insulation, blankets or
water pipe insulation to this water heater will require
careful attention to the following:
* Do not cover the temperature and pressure-relief
valve.
* Do not cover access panels to the heating elements.
* Do not cover the electrical junction box of the
water heater.
* Do not cover the operating or warning labels attached
to the water heater or attempt to relocate them on
the exterior of the insulation blanket.
* Do not block the air inlet/outlets in the top covers or
rear of the unit.
NOTE: This guide recommends minimum branch
circuit sizing based on the National Electric Code.
Refer to wiring diagrams in this manual for field wiring
connections.
BRANCH CIRCUIT SIZING GUIDE
Totalwater
Heater wattage
3,000
4,000
4,500
5,000
5,500
6,000
8,000
9,000
10,000
11,000
12,000
Recommended 0verCurrent
Protection
(fuse or c rcu t breaker amperage rat ng)
208V
240V
277V
480V
20
20
15
15
25
25
20
15
30
25
25
15
30
30
25
15
35
30
25
15
40
35
30
20
50
45
40
25
-
50
45
25
-
50
30
-
50
30
-
-
35
T0talWater
Heater Wattage
3,000
4,000
4,500
5,000
5,500
6,000
8,000
9,000
10,000
11,000
12,000
coppe r Wile size AWG Based
on N.E.C. Tab e 310,16 (167 F/75 C.)
208V
240V
277V
480V
12
12
14
14
I0
I0
12
14
i0
i0
i0
14
I0
I0
I0
14
8
10
10
14
8
8
10
12
8
8
8
10
8
8
10
8
10
8
10
-
8
18

Hide quick links: